COMe-cVR6 – User Guide Rev. 1.5
// 45
5/
Environmental Specification
5.1.1.
Temperature
Kontron defines the following temperature grades for Computer-On-Modules. For more information on the available
temperature grades for the COMe-cVR6, see Chapter 2.1 Module Variants.
Table 56: Temperature Grade Specifications
Temperature Grades
Operating
Non-operating / Storage
Commercial Grade
0°C to +60°C
-30°C to +85°C
Extended Grade E1
(custom)
-25°C to +75°C
-30°C to +85°C
Industrial Grade E2S
(by screening)
-40°C to +85°C
-40°C to +85°C
5.1.2.
Humidity
Table 57: Humidity Specification
Humidity
Relative Humidity
93% at 40°C non-condensing (according to IEC 60068-2-78)
5.2.
Standards and Certifications
The COMe-cVR6 complies with the following standards and certifications. For more information, contact Kontron
Support.
Table 58: Standards and Certification Compliance
Standard
Definition
Emission
(EMC)
EN 55022: Class B: Information technology equipment - Radio disturbance characteristics-
Limits and methods of measurement
IEC /EN 61000-6-3 :Electromagnetic compatibility (EMC)- Part 6-3: Generic Standards-
Emission standard for residential, commercial and light-industrial environments
IEC/ EN 61000-3-2: Harmonic current emissions
IEC / EN 61000-3-3: Voltage changes, voltage fluctuations and flicker
Immunity
(EMI)
IEC / EN 61000-6-2: Electromagnetic compatibility (EMC) – Part 6-2: Generic standards -
immunity for industrial environments
Immunity tests:
IEC / EN 61000-4-2 - Electrostatic discharge immunity (ESD)
IEC / EN 61000-4-3 – Radiated, radio frequency, electromagnetic field immunity
IEC / EN 61000-4-4 - Electrical fast transient/burst immunity
IEC / EN 61000-4-5 - Surge immunity
IEC / EN 61000-4-6 - Immunity to conducted disturbances, induced by radio frequency fields
IEC / EN 61000-4-8 - Power frequency magnetic field Immunity
IEC / EN 61000-4-11 - Voltage dips, short interruptions, & voltage variation immunity