Standards and Certifications
The COMe-mEL10 complies with the following standards and certificates. If modified, the prerequisites for specific
approvals may no longer apply. For more information, contact Kontron Support.
Table 13: Standards and Certifications
EMC
Emission
EN 55032 Class B
CISPR32
Electromagnetic compatibility of multimedia equipment -
Emission requirements
Immunity
IEC / EN 61000-6-2
Electromagnetic compatibility (EMC) Part 6-2: Generic
standards - Immunity standard for industrial environments
Safety
Europe
EN 62368-1
Safety for audio/video and information technology equipment
USA & Canada
UL 62368-1/CSA 62368-1
(Component Recognition)
Recognized by Underwriters Laboratories Inc. Representative
samples of this component have been evaluated by UL and
meet applicable UL requirements.
UL listings:
AZOT2.E147705
AZOT8.E147705
Environment
Shock
IEC / EN 60068-2-27
Non-operating shock test
(half-sinusoidal, 11 ms, 15 g)
Vibration
IEC / EN 60068-2-6
Non-operating vibration
(sinusoidal, 10 Hz – 2000 Hz, +/- 0.15 mm, 2 g)
RoHS II
Directive 2011/65/EU incl.
2015/863/EU
Restriction of Hazardous Substances
in electrical and
Electronic Equipment (RoHS)
2.7.1.
MTBF
The MTBF (Mean Time Before Failure) values were calculated using a combination of the manufacturer’s test data, (if
available) and the Telcordia (Bellcore) issue 2 calculations for the remaining parts.
The Telcordia calculation used is “Method 1 Case 3” in a ground benign, controlled environment. This particular method
takes into account varying temperature and stress data and the system is assumed to have not been burned-in. Other
environmental stresses (such as extreme altitude, vibration, salt-water exposure) lower MTBF values.
Table 14: MTBF
MTBF
System MTBF (hour) = 513232 h @ 40°C for COMe-mEL10 J6426
Reliability report article number: 34012-0432-J2-4
System MTBF (hour) = 508437 h @ 40°C for COMe-mEL10 E2 x6425RE
Reliability report article number: 34013-0832-R2-4