KBox A-150-SKL - User Guide Rev. 1.1
// 70
2.
Replace with a new lithium battery by inserting the battery’s connector into the on-board battery power input
connector (Figure 43, pos. 3), while paying attention to the polarity of lithium battery connector cables.
Figure 43: Lithium Battery Power Input Connector
1
Lithium battery (CR 2032, 3 V )
2
Lithium battery cable
3
Battery power input connector
3.
Position the battery cable to ensure that the cables do not interfere with other components and attach the
lithium battery to the top of the internal USB 3.0 connector (Figure 42, pos. 2), using a double-sided adhesive pad.
4.
Close the KBox A-150-SKL as described in Chapter 6.2: Opening the System (step 7)
Danger of explosion when replacing with wrong type of battery. Replace only with the same
or equivalent type recommended by the manufacturer. The lithium battery type must be UL
recognized.
The KBox A-150-SKL is not designed to operate without a battery. If the battery is empty or
disconnected, the BIOS settings will be set to the factory defaults.
Do not dispose of lithium batteries in general trash collection. Dispose of the battery according
to the local regulations dealing with the disposal of these special materials, (e.g. to the
collecting points for dispose of batteries).
3
2