KSwitch D1 UGPD Unmanaged Gigabit PoE Ethernet Switch - Preliminary User Guide, Rev. 0.9
// 29
To install the wall mount L brackets supplied in the Wall Mount Kits, perform the following:
1.
Make sure the mounting surface is clean and smooth and meets the thickness requirement of the screw.
2.
Aline each wall mount L brackets to the correct threaded holes on the sides (left, right) of the switch.
Mount on a wall or flat surface using the correct number of wall mount L brackets and
screws to ensure the switch is secured properly.
3.
Fasten the wall mount L brackets to the switch using the screws provided.
4.
Mount the switch to a wall or flat smooth surface by inserting screws with a suitable length for the mounting
surface into each key mounting hole on the wall mount L bracket (Figure 14, pos. 2) or inserting screws with a
suitable length for the mounting surface into each mounting hole on the wall mount L bracket(Figure 14, pos. 3)
and fastening firmly.
Figure 16: Mounting Dimensions Wall Mount L Bracket
The mounting surface holes must be 3.6 mm or 6.5 mm in diameter and 9.1 mm away from
the left or right sides of the switch.