KSwitch D3 UM Unmanaged Fast Ethernet Switch - Preliminary User Guide, Rev. 0.9
// 22
4.1.4.
DC Terminal Block Power Contacts (18-port, 26-port and 50-port)
The switch can be powered from dual external DC power supplies (input range of 12 VDC to 58 VDC) by inserting the
positive and negative wires into the corresponding contacts for the first power supply P1+/- and second power
supply P2+/- on the DC terminal block and tightening the wire-clamp screws to prevent the wires from loosening.
The switch supports fault alarm notification for power. To check for correct operation, refer to the LED indicators ‘P1’
and ‘P2’ on the faceplate.
Figure 6: Power Contacts (18-port, 26-port and 50-port)
1
P1 +/- contacts
2
P2 +/- contacts
When connecting the power follow the polarity indicated for P1 +/-and P2+/-.
When attaching power wires to the DC terminal block’s power contacts consider:
•
DC terminal block pitch, 5.08 mm
•
Wire size range: Solid wire: 12~24 AWG and Stranded wire: 12~24 AWG
•
Wire length 3 m (9.84 ft.) maximum
•
Wire strip length 7 mm (0.28 in)
With multiple power sources connected to the switch, the switch utilizes the power supply
with the higher voltage or the most stable power supply.