USB 3.1 Port --- Type C 

 

Table 8: USB 3.1 Port --- Type C (see Figure 1, pos. 5) 

Pin 

Signal Name 

24-pin USB Connector Type A Version 3.1 / 2.0 

A1 

GND 

 

A2 

A3 

USB3_TX1- 

A4 

VCC AUX 

A5 

Config. Channel 1 

A6 

USB2 Data+ 

A7 

USB2 Data- 

A8 

Sideband1 

A9 

VCC AUX 

A10  USB3_RX2- 
A11 

A12 

GND 

B1 

GND 

B2 

B3 

USB3_TX2- 

B4 

VCC AUX 

B5 

Config. Channel 2 

B6 

USB2 Data+ 

B7 

USB2 Data- 

B8 

Sideband2 

B9 

VCC AUX 

B10  USB3_RX1- 
B11 

B12 

GND 

 

11.4.

 

USB 3.1 Port --- Type A 

 

Table 9: USB 3.1 Port --- Type A (see Figure 1, pos. 4 & Figure 2, pos. 5) 

USB 2.0 Contact Pin 

USB 3.1 Contact Pin 

9-pin USB Connector Type A Version 3.1 / 2.0 

Pin 

Signal Name 

Pin 

Signal Name 

VCC AUX 

USB3_RX- 

 

USB2_Data- 

 

US 

GND 

GND 

USB3_TX- 

 

 

 

 

 

Summary of Contents for Kontron SBOX-5210

Page 1: ...USER GUIDE www kontron com SBOX 5210 Doc User Guide Rev 1 0 Doc ID To be Determined...

Page 2: ...SBOX 5210 User Guide Rev 1 0 www kontron com 2 This page has been intentionally left blank...

Page 3: ...be suitable for the specified use without further testing or modification Kontron expressly informs the user that this user guide only contains a general description of processes and instructions whic...

Page 4: ...y at your risk To minimize the risks associated with your products and applications you should provide adequate design and operating safeguards You are solely responsible for compliance with all legal...

Page 5: ...t Find Kontron contacts by visiting http www kontron com support Customer Service As a trusted technology innovator and global solutions provider Kontron extends its embedded market strengths into a s...

Page 6: ...cribed by the law may endanger your life health and or result in damage to your material ESD Sensitive Device This symbol and title inform that the electronic boards and their components are sensitive...

Page 7: ...before performing any work on this product Earth ground connection to vehicle s chassis or a central grounding point shall remain connected The earth ground cable shall be the last cable to be disconn...

Page 8: ...oduct then re pack it in the same manner as it was delivered Special care is necessary when handling or unpacking the product See Special Handling and Unpacking Instruction Quality and Environmental M...

Page 9: ...2 1 Electromagnetic Compatibility EU 17 2 2 FCC Statement USA 17 2 3 EMC Compliance Canada 17 3 Shipment and Unpacking 18 3 1 Unpacking 18 3 2 Scope of Delivery 18 3 2 1 Standard 18 3 2 2 Optional Pa...

Page 10: ...VESA Mounting 40 7 2 DC Power Connection 43 8 Start Up 44 8 1 Connecting to DC Power Supply 44 8 2 Operating System and Hardware Component Drivers 45 9 Maintenance and Cleaning 46 10 Technical Specif...

Page 11: ...w Top Side without cover 26 Figure 6 Descrewing the rear access cover of the SBOX 5210 29 Figure 7 Pulling down the rear access cover and sliding backward the top access cover 29 Figure 8 Descrewing t...

Page 12: ...tion 71 Figure 37 BIOS Advanced Menu Graphic Configuration 72 Figure 38 BIOS Advanced Menu Realtek PCIe GBE Family Controller MAC 4C 52 62 BC A5 94 73 Figure 39 BIOS Security Setup Menu 74 Figure 40 B...

Page 13: ...sufficient air circulation is available to cool the product please ensure that the ventilation openings are not covered or blocked If an air filter is provided this should be cleaned regularly Do not...

Page 14: ...ndirectly a reliable protective earthing connection is provided a suitable easily accessible disconnecting device is used in the application e g overcurrent protective device if the device itself is n...

Page 15: ...non conductive materials such as ordinary plastic assembly aids and Styrofoam 7 Use only field service tools which are conductive such as cutters screwdrivers and vacuum cleaners 8 Always place drive...

Page 16: ...on com 16 Do not dispose of lithium batteries in general trash collection Dispose of the battery according to the local regulations dealing with the disposal of these special materials e g to the coll...

Page 17: ...ed and used in accordance with the instructions may cause harmful interference to radio communications However there is no guarantee that interference will not occur in a particular installation If th...

Page 18: ...inconsistencies between the contents and your order please contact Kontron for help and information 3 2 Scope of Delivery 3 2 1 Standard 1x SBOX 5210 corresponding to the ordered system configuration...

Page 19: ...e connector from onboard SATA data connector and power connector for 2 5 SATA HDD SSD 1x M 2 Key E socket M 2 WLAN Type 2230 1x M 2 Key M socket M 2 PCIe Type 2280 The device is designed to be operate...

Page 20: ...or and power connector The interface is SATA 3 0 compatible Users can expand the system with a 2 5 SATA HDD SSD drive 4 1 2 System Expansion via M 2 Interface The baseboard comes with two onboard M 2...

Page 21: ...The system must be attached by means of the power cord to an appropriate mains DC Even when the system is turned off via the power button there is still a standby voltage on the baseboard The unit is...

Page 22: ...nnect the microphone used for video conferencing voice narrations or simple audio recordings 4 2 4 USB 3 1 The front I O panel of the SBOX 5210 provides two USB 3 1 2 0 interfaces One is of Type A and...

Page 23: ...wer supplied through this jack supplies power to the PC To prevent damage to the PC always use the supplied power adapter Adapter s power cord shall be connected to a socket outlet with earthing conne...

Page 24: ...or USB 2 0 compatible device to the system 4 3 6 USB 2 0 The rear I O panel of the SBOX 5210 provides two USB 2 0 1 1 interfaces with Type A connectors These connectors allow connection of USB compati...

Page 25: ...Security Slot see Chapter 4 4 1 4 4 1 Kensington Security Slot The slot is used for attaching a lock and cable apparatus Locks are generally secured in place with a key or combination lock attached t...

Page 26: ...2 3 Hard Drive Power Connector see Chapter 4 4 2 4 SATA Data Power Combo Cable see Chapter 4 4 2 5 SATA Data Power Combo Connector see Chapter 4 4 2 6 SATA Data Plug see Chapter 4 4 2 7 Hard Drive Po...

Page 27: ...onnector Figure 5 pos 3 In case it is packed separately per ordered configuration connect the SATA data plug Figure 5 pos 6 and hard drive power plug Figure 5 pos 7 to the onboard SATA data connector...

Page 28: ...in this manual Only personnel with appropriate qualifications trainings and authorization are permitted to install and work with the device The installation removal of HHD SSD and or expansion cards m...

Page 29: ...ing and closing the SBOX 5210 please perform the following steps 1 Close all applications Shut down the system properly and disconnect the connection to the main power source Disconnect all peripheral...

Page 30: ...rear access covers to the system and screw the rear access cover on with the retained screws 13 Tighten the retained screws when the covers are firmly in place When used as intended the SBOX 5210 is t...

Page 31: ...er to close the device proceed step 10 13 described in the subsection 5 1 Opening and Closing the Chassis 5 1 3 Installing An M 2 SSD To install an M 2 SSD please proceed according to the steps descri...

Page 32: ...SBOX 5210 User Guide Rev 1 0 www kontron com 32...

Page 33: ...provide a maximum of airflow through and around the box proper distances to surrounding parts must be observed 6 4 Maximum Temperatures The maximum system ambient temperature depends mostly on the pow...

Page 34: ...d and configured with third party components like M 2 expansion card and hard drives HDD or SSD it has to be taken into account that the air temperature inside the system is higher than the ambient te...

Page 35: ...bility for any and all damages resulting from operation of the unit with foreign objects inside the chassis The SBOX 5210 has to be installed and operated only by trained and qualified personnel Only...

Page 36: ...OX 5210 configuration with a VESA mounting kit for vertical installation on the back of a monitor on a wall other support surface or inside a custom enclosure machine 7 1 1 Desktop Installation Horizo...

Page 37: ...Chassis Desk Stand 2 Screw To install the SBOX 5210 please proceed according to the steps described 1 Place the chassis desk stand Figure 11 pos 1 onto the left side of the chassis by aligning it scre...

Page 38: ...nt brackets Figure 13 pos 1 and four screws Figure 13 pos 2 Figure 13 Wall mount kit 1 Wall Mount Bracket 2 Screw Figure 14 Hole pattern of wall mount kit for SBOX 5210 unit mm To install the SBOX 521...

Page 39: ...4 Secure the wall mount brackets to the chassis by the supplied screws Figure 13 pos 2 5 Place the SBOX 5210 on the mounting surface and then secure it to the mounting surface by screwing the wall mou...

Page 40: ...cross head screws Figure 16 pos 2 and four thumb head screws with hanger knobs Figure 16 pos 3 Figure 16 Optional VESA mounting kit 1 VESA Adapter 2 Cross head Screw 3 Thumb Screw with Hanger Knob The...

Page 41: ...lowing figures take VESA mounting to a monitor as an example Figure 18 Securing the thumb screws 3 Align the screw holes marked number 2 on the VESA adapter with the holes on the bottom side of the ch...

Page 42: ...he SBOX 5210 on the mounting surface 7 Now the SBOX 5210 is firmly hanged on the mounting surface For a sufficient air circulation around the device we recommend keep a proper clearance and not mount...

Page 43: ...2 DC Power Connection The SBOX 5210 is connected by a DC power input jack Figure 2 pos 1 to a DC power source The SBOX 5210 is delivered with a power adapter to convert AC voltage into DC 19 V and a...

Page 44: ...nnections attached to the system should be the power wires The SBOX 5210 must be connected DC main power supply complying with the SELV Safety Extra Low Voltage requirements of EN 60950 1 standard It...

Page 45: ...ts Your system is fully operational when you switch it on for the first time If you have ordered the SBOX 5210 without a pre installed operating system you will need to install the operating system an...

Page 46: ...for proper operation For light soiling clean the SBOX 5210 with a dry cloth Carefully remove dust from the surface of the chassis using a clean soft brush Stubborn dirt should be removed using a mild...

Page 47: ...ion Ethernet 1x GbE LAN RJ45 on rear Realtek RTL8111E Peripheral Connection USB 4x USB 3 1 2x Type A on rear 1x Type A on front 1x Type C on front 2x USB 2 0 Type A on rear Storage Expansion Storage E...

Page 48: ...Table 3 Mechanical Specifications Construction Metal Chassis with Plastic Front I O Panel Dimensions W x D x H 36 mm x 165 mm x 147 mm 1 42 x 6 50 x 5 79 Weight 800 g 1 76 lb Mounting Wall Mount VESA...

Page 49: ...nvironmental Conditions Table 4 Environmental Conditions Operating Temperature 0 C 40 C 32 F 104 F Storage Temperature 20 C 80 C 4 F 176 F Humidity 5 85 10 3 Standards and Certifications Table 5 Stand...

Page 50: ...nals are indicated by a minus sign 11 1 DC Power Input Table 6 DC Power Input see Figure 2 pos 1 Pin Signal Name DC Jack female 1 19V DC 2 GND 11 2 Ethernet Connector Table 7 Ethernet Connector see Fi...

Page 51: ...A9 VCC AUX A10 USB3_RX2 A11 USB3_RX2 A12 GND B1 GND B2 USB3_TX2 B3 USB3_TX2 B4 VCC AUX B5 Config Channel 2 B6 USB2 Data B7 USB2 Data B8 Sideband2 B9 VCC AUX B10 USB3_RX1 B11 USB3_RX1 B12 GND 11 4 USB...

Page 52: ...ctor Type A Version 2 0 1 5V 2 Data 3 Data 4 GND 11 6 DP Connector Table 11 DP Connector see Figure 2 pos 2 Pin Signal Name DP Connector 1 Link0 2 GND 3 Link0 4 Link1 5 GND 6 Link1 7 Link2 8 GND 9 Lin...

Page 53: ...10 TMDS Clock 11 GND 12 TMDS Clock 13 NC 14 NC 15 DDC Clock 16 DDC Data 17 GND 18 5V Power 19 Hotplug Detect 11 8 Line Out Connector Table 13 Line Out Connector see Figure 1 pos 2 Pin Signal Name Lin...

Page 54: ...it until the first characters appear on the screen POST messages or splash screen 3 Press the F2 key 4 If the uEFI BIOS is password protected a request for password will appear Enter either the User P...

Page 55: ...em Specific Help window providing an explanation of the respective function 12 2 1 Main Setup Menu Upon entering the uEFI BIOS Setup program the Main Setup menu is displayed This screen lists the Main...

Page 56: ...anguage English F1 General Help F2 Previous Values Access Level Administrator F3 Optimized Defaults F4 Save Exit Keyboard Layout English ESC Exit Version 2 20 1271 Copyright C 2019 American Megatrends...

Page 57: ...Customer Serial Number Board Serial Number 62756725 Ident Number UUID 3206B6A2 2583 4CD9 9A91 77F3CF60A3D8 Network Controller Details LAN 1 MAC Address 4C 52 62 BC A5 94 Select Screen Select Item Pro...

Page 58: ...Software License Information This system board contains Open Source Software Select Screen For license details please visit the following web site Select Item Enter Select http support ts fujitsu com...

Page 59: ...ons are included in the menu Onboard Devices Configuration Auto BIOS Update CPU Configuration Drive Configuration SMART Settings Trusted Computing USB Configuration System Management AMT Configuration...

Page 60: ...te CPU Configuration Drive Configuration SMART Settings Select Screen Trusted Computing Select Item USB Configuration Enter Select System Management Change Opt AMT Configuration F1 General Help Networ...

Page 61: ...n Enabled Select Screen Select Item Audio Configuration Enter Select Azalia HD Audio Enabled Change Opt F1 General Help WLAN Bluetooth Enabled F2 Previous Values F3 Optimized Defaults F4 Save Exit ESC...

Page 62: ...Description Terms of use Decline Accept Please accept the terms of use to activate this feature The terms of use can be found in the BIOS manual or online at tou ts fujitsu com Remember By using this...

Page 63: ...ckage Intel Virtualization Technology Disabled Enabled When enabled a VMM can utilize the additional hardware capabilities provided by Vanderpool Technology VT d Disabled Enabled Enable Disable Intel...

Page 64: ...em Enter Select OnBoard SATA Configuration Change Opt F1 General Help SATA Port 0 Not Installed F2 Previous Values Port 0 Enabled F3 Optimized Defaults External SATA Disabled F4 Save Exit Hot Plug Dis...

Page 65: ...s Boot Save Exit SMART Settings SMART Self Test Enabled Select Screen Select Item Enter Select Change Opt F1 General Help F2 Previous Values F3 Optimized Defaults F4 Save Exit ESC Exit Version 2 20 12...

Page 66: ...M 2 0 Device Found F1 General Help Firmware Version 403 1 F2 Previous Values Vendor INTC F3 Optimized Defaults F4 Save Exit ESC Exit Version 2 20 1271 Copyright C 2019 American Megatrends Inc These it...

Page 67: ...ILITY Main Advanced Security Power Event Logs Boot Save Exit USB Configuration USB Devices Select Screen 1 Keyboard Select Item Enter Select USB Port Security Change Opt F1 General Help F2 Previous Va...

Page 68: ...nable front and internal ports Enable rear and internal ports Enable internal ports only Enable used ports Configures how USB ports are enabled Enable all ports All USB ports are enabled Disable all p...

Page 69: ...General Help VCC 3 3V 3388 mV F2 Previous Values 3 3V AUX 3388 mV F3 Optimized Defaults V_IN 19V 19262 mV F4 Save Exit VBAT 3 0V 2743 mV ESC Exit Version 2 20 1271 Copyright C 2019 American Megatrend...

Page 70: ...SETUP UTILITY Main Advanced Security Power Event Logs Boot Save Exit AMT Configuration ME Version 12 0 35 1427 Select Screen Select Item Enter Select Change Opt F1 General Help F2 Previous Values F3...

Page 71: ...General Help F2 Previous Values F3 Optimized Defaults F4 Save Exit ESC Exit Version 2 20 1271 Copyright C 2019 American Megatrends Inc These items appear only when enabling Network Stack Feature Optio...

Page 72: ...are activated only when selecting Auto or Enabled for Internal Graphics Feature Option Description Primary Display Auto Internal Graphics PCI Express for Graphics PEG PCI Express Select which graphics...

Page 73: ...Version 2 040 Driver Released Date 2017 03 09 Select Screen Device Information Select Item Device Name Realtek PCIe GBE Family Controller Enter Select PCI Slot 01 00 00 Change Opt MAC Address 4C 52 62...

Page 74: ...up In Setup the User will have USER rights The password length must be in the following range Minimum length 3 Maximum length 32 Minimum User Password Length 4 Supervisor Password Select Screen User P...

Page 75: ...e System firmware version Windows Update WU is blocked System Firmware Rollback Disabled Enabled Specifies if it is allowed to rollback BIOS to an older version If only the administrator s password is...

Page 76: ...eral Help Secure Boot Mode Standard F2 Previous Values F3 Optimized Defaults Key Management F4 Save Exit ESC Exit Version 2 20 1271 Copyright C 2019 American Megatrends Inc This sub menu is activated...

Page 77: ...ult Secure Boot keys after the platform reset and while the System is in Setup mode Enroll all Factory Default Keys Yes No Force System to User Mode Install factory default Secure Boot key databases S...

Page 78: ...SBOX 5210 User Guide Rev 1 0 www kontron com 78 Feature Option Description Authorized TimeStamps Set New Key Append Key OsRecovery Signatures Set New Key Append Key...

Page 79: ...a record of all passwords in a safe place Forgotten passwords results in being locked out of the system If the system cannot be booted because the User Password or the Supervisor Password are not know...

Page 80: ...Minute 1 Second 0 Wake Up Mode Daily Sunday 1 Disabled Monday 1 Disabled Tuesday 1 Disabled Wednesday 1 Disabled Thursday 1 Disabled Friday 1 Disabled Saturday 1 Disabled Wake Up Day 2 1 Select Screen...

Page 81: ...Force LAN Boot Force LAN boot after Wake On LAN PXE boot options must be enabled to actually force a network boot USB Keyboard Disabled This field is not selectable Wake Up Timer Disabled Enabled Allo...

Page 82: ...ange Smbios Event Log Settings View Smbios Event Log Figure 43 BIOS Event Logs Setup Menu BIOS SETUP UTILITY Main Advanced Security Power Event Logs Boot Save Exit Change Smbios Event Log Settings Vie...

Page 83: ...escription Smbios Event Log Disabled Enabled Change this to enable or disable all features of Smbios Event Logging during boot Erase Event Log No Yes Next reset Yes Every reset Choose options for eras...

Page 84: ...ot Disabled Enabled Enables or disables Quiet Boot option Logo Resolution Default Resolution Native Resolution Static Resolution Configures the screen resolution Default Resolution Default screen reso...

Page 85: ...5210 User Guide Rev 1 0 www kontron com 85 Feature Option Description Boot Removable Media Disabled Enabled This option enables disables support for booting to removable devices such as USB flash dri...

Page 86: ...tem Restore Defaults Enter Select Change Opt Boot Override F1 General Help Diagnostic Program F2 Previous Values F3 Optimized Defaults F4 Save Exit ESC Exit Version 2 20 1271 Copyright C 2019 American...

Page 87: ...ive HDMI High Definition Multimedia Interface LAN Local Area Network LED Light Emitting Device LVDS Low Voltage Differential Signaling ME F W Management Engine Firmware mPCIe mini Peripheral Component...

Page 88: ...solutions based on highly reliable state of the art embedded technologies Kontron provides secure and innovative applications for a variety of industries As a result customers benefit from accelerate...

Reviews: