background image

Technical Data

Transmitter
Power supply: 

 

 

 

4 Alkaline batteries 1.5V (type AAA)

Battery 

lifespan: 

   1 

year

Temperature adjustment range: 

 

5 to 35

o

Temperature display range: 

 

0 to 50

o

Temperature display scale:  

 

0.1

o

Temperature adjustment scale: 

 

0.5

o

Operating temperature: 

 

 

0 to 50

o

C

Switching 

differential: 

  0.5/1.0

o

C selectable 

Clock 

accuracy: 

   <1 

sec/day

Protection 

rating: 

   IP30

Pollution 

class: 

   3 

Flexiable wire Size: 

 

 

0.5-1.5mm

2

Rigid 

wire 

Size: 

   0.5-2.5mm

2

Pollution 

class: 

   3

Dimensions: 

   L110.8xH104xD21.5 

Transmission 

frequency: 

  433.92Mhz

Receiver
Power 

supply: 

   230Vac 

50Hz 

Contact rating:   

 

 

16A, 250Vac (Volt free changeover contacts)

Radio 

frequency: 

   433.92Mhz

Receiver 

category:   2 

Protection 

rating: 

   IP43 

Insulation 

class: 

   11

Operating temperature: 

 

 

-10 to 60

o

C

Storage temperature: 

 

 

-10 to 60

o

C

Flexible wire size: 

 

 

0.5-1.5mm

Rigid 

wire 

size: 

   0.5-2.5mm

2

Dimensions: 

   L88xH88xD39.4

Receiver wall mount box: 

 

Included

Complies with:   

 

 

EN60730-1, EN60730-2-1, EN60730-2-7,  

 

  

 

 

 

 

EN60730-2-11, EN60950-1, EN60950-1/A11,  

 

     EN12098-2, 

EN12098-5, 

EN301-489-3, 

 

 

     EN300-220-1, 

EN300-220-2, 

EN301-489-1 

Page 2

Page 7

Temperature Until (Vacation Hold)

Hold temperature at the desired set point till a specified date reached where upon thermostat returns 
to its original programming.

Press Mx3

Temp Set flashing

Adjust by +/- 

Press OK

Month flashing

Adjust by +/- 

Press OK

Day flashing

Adjust by +/- 

Press OK

Year flashing

Adjust by +/- 

Press OK

Hold Temp Until, Date & Temp set displayed

Press OK

To cancel and return to Run mode

Reset (Erase Memory)

To erase the current settings and return to its default settings and programms

Press OK and 

    

for 6 secs

Reset displayed

Press Reset button

All segments displayed for short period, unit returns to default settings

Summary of Contents for CHOICE RSTAT5

Page 1: ...LEASE DO NOT TRY TO DISMANTLE THE UNIT This product is guaranteed by your supplier for 3 years from the Date of Manufacture If it should become defective please contact your installer or supplier for a replacement unit or visit www sangamo co uk returns An extended warranty may be purchased online www sangamo co uk warranty CUSTOMER CARE POLICY As part of Sangamo s continuous improvement program t...

Page 2: ...60 o C Storage temperature 10 to 60 o C Flexible wire size 0 5 1 5mm 2 Rigid wire size 0 5 2 5mm 2 Dimensions L88xH88xD39 4 Receiver wall mount box Included Complies with EN60730 1 EN60730 2 1 EN60730 2 7 EN60730 2 11 EN60950 1 EN60950 1 A11 EN12098 2 EN12098 5 EN301 489 3 EN300 220 1 EN300 220 2 EN301 489 1 Page 2 Page 7 Temperature Until Vacation Hold Hold temperature at the desired set point ti...

Page 3: ...the programming sequence you can copy a days program settings into other days Press SETx2 Choose From reference day Select by Press OK Choose To day Select by Press OK Repeat as required for next To day Select by Press To delete a selected To day Press OKx2 To accept return to Run Mode Temporary Override Change temperature until next programmed set point Press Temporary Override Temp Set displayed...

Page 4: ...ransmitter You may select a different RF address code to prevent this Position both Transmitter and Receiver DIP Switches with the same arrangement Flip to open the flap on front plastic housing Upper compartment 2 x 1 5V AAA for powering Thermostat Lower compartment 2 x 1 5V AAA for backlight Default Program up down keys M Override function control keys Set Programming Selection Reset Reset Therm...