Technical Data
Transmitter
Power supply:
4 Alkaline batteries 1.5V (type AAA)
Battery
lifespan:
1
year
Temperature adjustment range:
5 to 35
o
C
Temperature display range:
0 to 50
o
C
Temperature display scale:
0.1
o
C
Temperature adjustment scale:
0.5
o
C
Operating temperature:
0 to 50
o
C
Switching
differential:
0.5/1.0
o
C selectable
Clock
accuracy:
<1
sec/day
Protection
rating:
IP30
Pollution
class:
3
Flexiable wire Size:
0.5-1.5mm
2
Rigid
wire
Size:
0.5-2.5mm
2
Pollution
class:
3
Dimensions:
L110.8xH104xD21.5
Transmission
frequency:
433.92Mhz
Receiver
Power
supply:
230Vac
50Hz
Contact rating:
16A, 250Vac (Volt free changeover contacts)
Radio
frequency:
433.92Mhz
Receiver
category: 2
Protection
rating:
IP43
Insulation
class:
11
Operating temperature:
-10 to 60
o
C
Storage temperature:
-10 to 60
o
C
Flexible wire size:
0.5-1.5mm
2
Rigid
wire
size:
0.5-2.5mm
2
Dimensions:
L88xH88xD39.4
Receiver wall mount box:
Included
Complies with:
EN60730-1, EN60730-2-1, EN60730-2-7,
EN60730-2-11, EN60950-1, EN60950-1/A11,
EN12098-2,
EN12098-5,
EN301-489-3,
EN300-220-1,
EN300-220-2,
EN301-489-1
Page 2
Page 7
Temperature Until (Vacation Hold)
Hold temperature at the desired set point till a specified date reached where upon thermostat returns
to its original programming.
Press Mx3
Temp Set flashing
Adjust by +/-
Press OK
Month flashing
Adjust by +/-
Press OK
Day flashing
Adjust by +/-
Press OK
Year flashing
Adjust by +/-
Press OK
Hold Temp Until, Date & Temp set displayed
Press OK
To cancel and return to Run mode
Reset (Erase Memory)
To erase the current settings and return to its default settings and programms
Press OK and
for 6 secs
Reset displayed
Press Reset button