 Installation Instructions

WARNING - ISOLATE THE MAINS 

BEFORE INSTALLATION & SERVICING

THIS INSTALLATION SHOULD BE CARRIED 

OUT BY A SUITABLY QUALIFIED PERSON, IN 

ACCORDANCE WITH THE CURRENT EDITION 

OF THE IEE WIRING REGULATIONS.
WARNING: All Powersaver products must 

be earthed, using the earth terminals at the 

rear of the switch. The following cabling is 

recommended:

L   & N   - 1.5mm² - 4.0mm² fixed

ê  ê

  - 1.5mm² - 2.5mm² flexible 

(retro fit applications (only in conjunction 

with 143609 surface box)

L  Out  & N Out - 1.5mm² - 2.5mm² fixed 

or flexible
Provision must be made in the fixed 

wiring for a means of disconnection from 

the supply having a contact separation 

of at least 3mm on all poles. This can be 

provided by the consumer unit.

The Powersaver product range are 

independently mounted time switches, 

of electronic construction, which can be 

surface or flush mounted. For flush fitting 

a metal box of at least 32mm internal 

depth should be fitted with the earth 

terminal at the bottom.

For surface mounting use a patress box 

with a minimum internal depth of 32mm.
Do not remove the Powersaver from its 

packaging until the patress/wall box is 

fitted and cleared of dust & debris. The 

Powersaver range is suitable for use in a 

normal pollution situation.
The cable clamp at the rear of the unit is 

for outgoing cables to the appliance only.

Fit & forget...

Powersaver

Daily 

(PSD)

Weekly

 (PSW)

24/7 

(PS24/7)

CONNECTION WARNING: Isolate mains 

before installing. Supply terminals are 

for fixed wiring only. Load terminals are 

for fixed or flexible wiring. Remove 8mm 

of insulation from each wire & twist any 

multiple connection together.
All earth conductors must be sleeved 

(green/yellow) and connected to earth 

terminals provided on rear of switch. Fit 

the Powersaver to the patress box using 

screws provided.
When cutting the aperture for the output 

flexible cord ensure no sharp edges 

remain.
PLEASE NOTE: This product is not suitable 

for mounting on unearthed metal or 

metallic surfaces.

Flush 

Mounting

Surface

Mounting

L

N Out

N

L Out

EARTH

LIVE

NEUTRAL

LOAD

MAINS IN

 Wiring Diagram

 Installation Diagrams

 Programming

BOOST

 (PSB)

The Powersaver Boost offers 3 options for 

the on period duration using the BOOST 

button.
Press once = ½ hour

Press twice = 1 hour

Press three times = 2 hour

Press four times = Cancel function
While the Boost is active the indicator 

light will change to show the maximum 

remaining time; e.g. 2 Hours selected

BOOST MAXI

 (PSB MAXI)

The Powersaver Boost Maxi performs 

exactly as the ‘Boost’ product but offers 

alternative on period durations using the 

BOOST button.
Press once = 1 hour

Press twice = 3 hours

Press three times = 5 hours

Press four times = Cancel function

DAILY, WEEKLY, 24/7 

(PSD, PSW, 

PS24/7)

 - See flap label for identification if in doubt

Program Methods:

1. 

Press SET to exit initial reset display 

if shown.

2.  Press SET to scroll through & review 

settings in sequence.

3. 

Press - & + to adjust these settings.

4. 

24/7 ONLY - Press BOOST to copy 

programs into the next day.

5.  24/7 ONLY - Press OFF/ON to skip to 

a day

6.  If a button is not pressed within 30 

seconds, the unit will revert back to 

the normal running state.

Typical Displays:

Date/Time Setting Mode

 

  

Reset/Initial 

      Set Time

Set Year  

      Set Month

Set Date

Program Setting Mode

Mon Tue Wed Thu Fri Sat Sun

18:88

AM

PM

PROG

8

OFF ON

  12:00

PM

 

  12:00

y

 

  1

n

 01

d

 

   12:00

AM

 

 

WEEKLY

PROG

1

ON

Mon Tue Wed Thu Fri 

   12:00

AM

 

 

 DAILY

PROG

1

ON

   12:00

AM

 

 

 24/7

PROG

1

ON

Mon

Mon Tue Wed Thu Fri 

Sat Sun

ERROR     BOOST

Reviews: