Contact Rating: 16A Resistive, 240V a.c.
Supply: 240V, 50-60Hz a.c.
Fixing: Single patress - surface & flush mounting
Resolution of Programs: 10 minutes
Auto Summer/Winter Time Change: Yes
Power Consumption: 10.3VA Maximum
Live Parts Protection: This unit is totally
protected by the enclosure
Dirt & Moisture Protection: IP40
Shock Protection: Class 1 (this must be
connected to earth)
Case Material: Polycarbonate, PT1 175
Temperature Rating: T35
Operating Temperature: 0°C to 35°C
Memory Reserve (except Boost): 4 hours - when
on power for previous 12 hours
Specification
Program Settings:
PSD
- Max 3 On & 3 Off operations (Daily) -
each day the same
PSW
- Max 3 On & 3 Off operations (Mon-Fri)
& Max 3 On & 3 Off alternative operations (Sat/
Sun).
PS24/7
- Max 3 On & 3 Off operations (7 days)
each day independently programmable.
Boost Facility: User selectable
PSB
- ½, 1 or 2 hours
PSB MAXI
- 1, 3 or 5 hours
Type of Action: Type 1B
Control Pollution Category: Normal
SERVICE AND WARRANTY
Your product is not user serviceable.
PLEASE DO NOT TRY TO DISMANTLE THE UNIT.
This product is guaranteed by your supplier for 5 years from the date of manufacture. If it should become defective
please contact your installer or supplier for a replacement unit or visit www.sangamo.co.uk/returns
This product must meet Waste Electronic and Electrical Equipment Regulations (WEEE) for suitable environmental
recycling, recovery and/or disposal. End of life products should be handled in line with local regulations. Alternatively
return end of life product to Sangamo for correct disposal.
CUSTOMER CARE POLICY
As part of Sangamo’s continuous improvement program, the company operates a Customer Care policy. This means
we welcome your comments and complaints, as it can help us to improve our services to you, our customer.
Due to our policy of continuous product improvement and development, the specifications in this guide may be
subject to change without prior notice.
Sangamo Limited
Industrial Estate, Port Glasgow,
Renfrewshire, PA14 5XG
Tel 01475 745131
Fax: 01475 744567
Email: enquiries@sangamo.co.uk
Web: www.sangamo.co.uk
WEE/JH0069TY
143082 Issue L
If you have a problem or require
any further information please
contact our technical team on:
01475 745131
Programming
(cont...)
Normal Display
Programming Display
(outwith program)
(during program)
Boost Mode
Holiday Mode
Keypad Locked
Programming Sequence
Daily
(PSD)
Time, Year, Month, Day,
Prog 1on, Prog 1off, Prog 2on, Prog 2off, Prog 3on, Prog 3off,
Return to normal display
Weekly
(PSW)
Time, Year, Month, Day,
Mon-Fri: Prog 1on, Prog 1off, Prog 2on, Prog 2off, Prog 3on, Prog 3off,
Sat-Sun: Prog 1on, Prog 1off, Prog 2on, Prog 2off, Prog 3on, Prog 3off,
Return to normal display
24/7
(PS24/7)
Time, Year, Month, Day,
Mon: Prog 1on, Prog 1off, Prog 2on, Prog 2off, Prog 3on, Prog 3off,
Tue: Prog 1on, Prog 1off, Prog 2on, Prog 2off, Prog 3on, Prog 3off,
Wed: Prog 1on, Prog 1off, Prog 2on, Prog 2off, Prog 3on, Prog 3off,
Thu: Prog 1on, Prog 1off, Prog 2on, Prog 2off, Prog 3on, Prog 3off,
Fri: Prog 1on, Prog 1off, Prog 2on, Prog 2off, Prog 3on, Prog 3off,
Sat: Prog 1on, Prog 1off, Prog 2on, Prog 2off, Prog 3on, Prog 3off,
Sun: Prog 1on, Prog 1off, Prog 2on, Prog 2off, Prog 3on, Prog 3off,
Return to normal display
Notes on Programming:
a) All programs must be in consecutive order, i.e. program 1 must be before
program 2 & program 2 before program 3. If the wrong order is programmed
error messages will be displayed
b) If only 2 or less programs are required, for the remaining programs enter
the same on & off times, e.g. Prog 3 on 8:00pm, off 8:00pm. This ensures
the unwanted program is cancelled.
c) Programming past midnight is NOT allowed. An error message will be
displayed. To overcome this the program needs to be split as per example-
Desired program period - on 10:00pm off 7:00am
make Prog 1 - on 12:00am off 7:00am
make Prog 2 - on 7:00am off 7:00am
make Prog 3 - on 10:00pm off 12:00am
Progs make up desired program period leaving prog 2 available for a program
during the day.
d) if you try to input the off time before the on time an error message will be
displayed. Press SET to continue.
Wed
6:15
PM
Wed
6:15
PM
PROG
3
ON
Wed
6:15
PM
OFF
12:00
L
Boost Function
Offers 3 options for on period duration outwith a program using the BOOST
button.
Press once = 30mins
Press twice = 1 hour
Press three times = 2 hours
Press four times = Cancel function
Duration can be extended or cancelled by successive presses.
Off (Holiday) Function
Allows you to suspend programmes whist still allowing the Boost function to
be used using the OFF/ON button
Press once = Suspend programs
Press twice = Cancel
NOTE: This is NOT an override function for programs.
NOTE: BOOST button is still active.
Program Override Function
If during a program On time you wish to cancel the program simply press the
BOOST button once.
NOTE: The program settings will not be affected & the next time this program
is due, it will function as normal. Adjoining programs will also be cancelled.
Product Reset (return to default settings)
Switch off power to unit.
Hold in BOOST button whilst switching power back on.
1 displayed = press BOOST
2 displayed = press SET
3 displayed = press -
4 displayed = press +
5 displayed = press OFF/ON
All LCD segments flashing displayed (reset) = press SET to reprogram.
Keypad Lock
Press - & + together for 5 seconds to lock settings = display briefly shows L
NOTE: BOOST button is still active
NOTE: display shows L when other buttons pressed
Press - & + together for 5 seconds to unlock settings.