background image

Above Ground, Filter Installation - Model 910

Apply teflon tape to each

threaded end of nipple.

Screw one end of nipple

into the filter return.

Screw either side of

Perform-Max on to open

nipple end until upright

and secure.

Tighten turning

1 to 2 revolutions with

wrench.  DO NOT OVERTIGHTEN.

HOSE

ADAPTER

HOSE

ADAPTER

HOSE  ADAPTER

6

Tighten turning

1 to 2 revolutions

with wrench.  DO NOT

OVERTIGHTEN

4.

5.

6.

1.

2.

3.

7.

MATERIALS NEEDED:

One

Hose

Clamp

Check Valve

Rainbow #172288

RECOMMENDED:

Apply teflon tape to

threaded end of hose

adapter.

Screw adapter into open

end of Perform-Max.

Attach return section of hose

to the adapter with clamp.

Tighten clamp with

screwdriver.

TOOLS NEEDED
Screwdriver

Installing a corrosion

resistant check valve is

recommended.

Teflon Tape

One Hose Adapter
1 1/2" X 1 1/2" X 1 1/4"

One 6" X 1 1/2"  TBE
PVC Nipple

One Section of
1 1/2" Flex Hose
(provided with filter)

Wrench

Summary of Contents for PERFORM-MAX 910

Page 1: ...P O O L S TRICHLOR L A R G E R S P A S S M A L L E R POOLS INSTRUCTION GUIDE Models 910 940 980 Inline Models 930 960 Off line Model 940 Model 910 PERFORM MAX POOL SANITIZER...

Page 2: ...lation 6 Inground Inline Installation 7 Off line Installation 8 9 Special Installations 10 Refilling Chemicals 11 Changing Chemicals 11 12 Setting Control Dial 12 Parts List 13 Replacing Control Dial...

Page 3: ...lowing important elements Water Balance Guidelines Free Chlorine 1 3 ppm Free Bromine 2 5 ppm pH 7 2 7 8 Total Alkalinity 60 120 Calcium Hardness 150 300 Total Dissolved Solids 2000 Stabilizer 20 50 p...

Page 4: ...romine See pages 5 6 DO NOT INSTALL OFF LINE Model 930 Off line for hard plumbed above ground pools Sanitizes up to 15 000 gallons using chlorine and up to 12 000 gallons using bromine Follow off line...

Page 5: ...pplicable TO POOL PUMP FILTER 5 1 2 3 4 5 1 to 2 revolutions with wrench DO NOT OVERTIGHTEN MA ERFORM POOLSANITIZER MATERIALS NEEDED Two Hose Clamps Check Valve Rainbow 172288 RECOMMENDED OPTION 1 1 2...

Page 6: ...1 to 2 revolutions with wrench DO NOT OVERTIGHTEN 4 5 6 1 2 3 7 MATERIALS NEEDED One Hose Clamp Check Valve Rainbow 172288 RECOMMENDED Apply teflon tape to threaded end of hose adapter Screw adapter...

Page 7: ...DED Wrench Hacksaw Following pipe thread sealant directions brush sealant onto Perform Max threads in both ports Brush sealant on the threads of both bushings DO NOT USE TEFLON TAPE as the threads on...

Page 8: ...adapters DO NOT USE TEFLON TAPE as the threads on these units are not suitable for this use and leaking or bushing failure could result Screw a male adapter into each port of Perform Max and hand tig...

Page 9: ...et scoop faces away from the water flow Tighten scoop clamps with a screwdriver When pipe is totally dry drill two 19 32 or 5 8 holes 12 apart on the return line Be careful not to go through other sid...

Page 10: ...P A S S M A L L E R PO OLS LARG ER P O O L S MA Perform Max 980 If installing a Model 980 Perform Max follow steps 1 through 3 on page 7 using the reducer bushing included with the Model 980 Repeat st...

Page 11: ...e cap by hand only DO NOT OVERTIGHTEN Replace side knob on Models 910 and 930 DO NOT USE CAP TOOL to tighten cap For removal only Turn pump off Use the cap tool included with Perform Max to loosen cap...

Page 12: ...TION 3 OPTION 4 OPTION 3 OPTION 2 OPTION 1 If over chlorinating Begin with Option 1 and continue with other options if necessary 2 For the first week or so test the water daily for free chlorine or br...

Page 13: ...01 22 9480 Pressure Relief Valve 1 5 6 7 01 22 1440 Control Dial with Assembly Kit 1 6 01 22 1450 Control Dial O Ring Set 1 7 01 22 1460 Control Dial Locking Pin 1 8 9 01 22 9940 Knob with O Ring 2 1...

Page 14: ...on o ring Use your finger to spread over surface 5 Carefully Insert control dial back into housing 6 Replace locking pin by pushing it through the slots on the valve until it locks into place 1 Using...

Page 15: ...of the other hand Roll o ring slightly back towards you as you stretch the o ring into the remainder of the cap groove 3 Lubricate o ring by squeezing a little silicone lubricant that came with your P...

Page 16: ...ormation concerning shock treatments B Control dial settings in excess of the recom mended setting levels for trichlor or bromine can result in excess sanitizers being discharged into our spa or pool...