background image

2

AC OR BATTERY POWERED

COLUMBIA SPECIFICATIONS  

SINK WITH ELECTRONIC SENSOR

800.626.2117   

columbiasinks.com

   info@

columbiasinks.com

©2021 Columbia Products

Installation Instructions

Step 1

1. Install strainer assembly.
2.  Attach bowl to pedestal base by slipping bolts on bowl through openings on pedestal base as 

shown in illustration A.

3. Tighten the 6 nuts to the threaded bolts under bowl. Do not over-tighten.

Step 2

1. Install faucets to the sink following the instructions provided with sensor unit.
2. Attach supply tube with elbow to back of faucet.
3. Install mixing check valve and compression fitting to control box of each sensor faucet.

Step 3

1. Place sink at the desired location.
2. Mark the floor where the four holes are at the pedestal base as shown in illustration B.
3. Drill holes as required for mounting hardware (Hardware not included).

Step 4

1. Secure sink to floor.
2. Connect waste line to strainer assembly.
1. Mount sensor control box at desired location on wall.
2. Connect power line from sensor to control box.
3. Attach supply tube from faucet to control box.
4. Connect hot and cold water from the source to mixing check valve.
5.  Remove aerator from the spout and flush water system. (see step 7 sensor installation 

instructions)

6. Check connections for leaks.
7. Replace aerator onto the spout.

Parts List

 (1) Sink bowl
 (1) Pedestal base
 (6) Nuts and washers to attach bowl to pedestal base
 (1) AC or battery powered sensor faucet assembly
 (1) Strainer assembly with basket 
 (1) Mixing check valve 

WARNING:

 This product can expose you to chemicals including Chromium (hexavalent compounds), 

Lead, and Phthalates (DEHP) which are known to the State of California to cause cancer and birth defects 
or other reproductive harm. For more information go to 

www.P65Warnings.ca.gov

.

NOTE

Lead content originates from Brass components in valves and faucets and is certified under 

NSF/ANSI 372 as containing less than 0.25% lead in wetted surfaces.

Notice for California Consumers

Tools Required

 Tape measure
 Adjustable wrench
 Drill motor and drill bits
 Pipe wrench
 Level
 Safety glasses
 Screw drivers: phillips and standard
 Pencil
 Socket wrench

Go to 

columbiasinks.com

 

for more information on replacement parts and installation videos.

Illustration A

Illustration B

Summary of Contents for ES2-521L

Page 1: ...loor Mount Stainless Steel Sink AC Models ES2 521L and ES2 521L 0 5 Battery Models ESB2 521L and ESB2 521L 0 5 of Domestic and Foreign Parts Columbia does not recommend use with harsh chemicals Product Compliance NSF ANSI 2 Food Equipment NSF ANSI 372 Lead Free Compliant ASME A112 18 1 ...

Page 2: ...box 3 Attach supply tube from faucet to control box 4 Connect hot and cold water from the source to mixing check valve 5 Remove aerator from the spout and flush water system see step 7 sensor installation instructions 6 Check connections for leaks 7 Replace aerator onto the spout Parts List 1 Sink bowl 1 Pedestal base 6 Nuts and washers to attach bowl to pedestal base 1 AC or battery powered senso...

Page 3: ...9 5 495mm 24 610mm 45º 10 5 267mm 10 5 267mm 9 5 241mm 10 254mm 22 559mm 1 25 R 32mm Hole Configuration Front Side Top 6 152mm 9 5 241mm 875 22mm dia key hole 6 5 165mm 21 533mm 19 483mm 2 drain hole 20 508mm 16 406mm 2 51mm 7 5 191mm 6 152 4mm 0 875 22 225mm 11 375 288 925mm 4 25 107 95mm Floor Mounting Detail 375 dia Floor Mounting Holes 4 25 on Center ...

Page 4: ...uality stainless steel cleaner and follow cleaner instructions Wipe along the grain NOT against Illustration D Things to Avoid Avoid harsh abrasive cleaners and corrosive chemicals Avoid abrasive scouring pads carbon steel brushes and steel wool for cleaning as iron particles left behind can lead to rust Avoid the use of oily rags or greasy cloths when wiping the surface To avoid water spots wipe ...

Page 5: ... Plug in Input AC 120V 60 Hz or 220V UL CSA Output DC 12V 0 8A Class 2 Power Cable Armored vandal resistant Optional Multi Unit Adapter Serves up to 8 faucets UL CSA Input AC 120V Output DC 12V 3A Battery Mode Battery Powered Models 4 AA Alkaline Batteries Battery Service Life 400 000 on off cycles up to 4 years Package Includes 1 Faucet with electronic sensor 1 Control box w 6V DC solenoid 1 12V ...

Page 6: ...he sink wall and tighten the faucet onto the sink using the O Ring 8 Washer 9 and Mounting Nut 10 Attach the 90 Degree Elbow 11 to the Supply Rod 7 USE TEFLON TAPE ONLY NO PIPE DOPE 5 Reconnect the Sensor Eye Cable 17 and Power Adapter 19 connections described in STEP 2 making sure the cables are seating in the Control Box 18 housing properly 6 Attach the Compression Fitting 13 to the Solenoid Val...

Page 7: ...id In line filter is clogged Open clean out trap and check filter screen Clean or replace filter screen Solenoid coil is defective Insert new batteries or reattach power adapter Light blinks but no solenoid is clicking Replace solenoid coil Flow control is clogged Open flow control device and check Celan the flow control device Faucet will not shut off has low glow or drips The solenoid valve is n...

Page 8: ...ring 6 Piston Piston Spring and check the Piston Sleeve for corrosion 6 Re install all parts in same order as the diagram below 7 Re install solenoid on the control box and re mount box in water line 8 Check and clean Filter Screen 24 in Filter Body 22 9 Reset P C Board and make sure solenoid clicks open and thumps closed 10 Turn on water and check for leaks and proper operation For further questi...

Page 9: ...CH Sw7 Sw8 Mode On Off Auto Faucet 6700C Series Sensor Operated Mixing Faucet Control Module Settings IMPORTANT Always push the Reset Button after any adjustments 1 2 3 4 5 6 7 8 Factory Preset Switch Position Shut Off Time Delay After hands are removed Sw1 Sw2 Sw3 Delay On On On 1 Sec On On Off 2 Sec On Off On 3 Sec On Off Off 4 Sec Off On On 5 Sec Off On Off 6 Sec Off Off On 7 Sec Off Off Off 8 ...

Reviews: