10
Dry Run Protection
IMPORTANT
• BEFORE USE check the magnetic impeller rotor is properly installed in the case motor assembly.
• BEFORE USE make sure that water is filled to at least 1 in (3 cm) above the jets for proper operation.
• DO NOT attempt to activate the jets on the Pipeless™ pedicure bath without water present.
DRY RUN PROTECTION
The Pipeless™ Pedicure Foot Bath is equipped with an advanced Dry Run Sensor to ensure water is present for proper
jet operation. When the motor is turned ON and no water is present, the motor will run in the “no load” condition for 30
seconds then shut off for 15 seconds . After 15 seconds the motor will turn back ON. If the motor does not sense a load after
8 seconds, it will shut off again for another 15 seconds . The motor will repeat this sequence a total of 10 times before going
into standby mode. Resetting the motor requires cycling the main power to the motors OFF and then back ON. (unplug
system and wait 5 seconds, then plug power supply back in again)
SAFETY SHUTOFF SENSOR
The Pipeless™ Pedicure Bath is equipped with a safety shutoff sensor. The jet assemblies must be properly installed for use
and will not operate if not aligned or assembled correctly.
The jet assemblies must be properly
locked in “run” position at the 3 or 9
o’clock position to operate.
The separator plate must be properly
installed in the escutcheon to operate.
3 o’clock
“run” Position
9 o’clock
“run” Position
Separator Plate
Sensor
Magnets
Escutcheon
Jet Discharge Port