Cleaning of steam generator
GEN6-3
Manual cleaning
1. Before cleaning the water tank, please be sure to drain water inside tank completely.
2. Power off the steam generator, put some oxalic acid (crystal state) via steam outlet, for example,
GEN6-3 9KW water tank need about 220g oxalic acid with 500-800ml hot water; pls be sure that
the manual water drain ball valve switch off this time.
3. After putted the oxalic acid inside tank, get power supply to steam generator but no turn it on.
Pressing Fly shuttle button for 2seconds, system will enter into the cleaning procedure, water will
fill the water tank automatically. TEMP window on panel shows “hot”, 59 minutes countdown time
begins and show on Timer window. steam generator will heat up water inside water tank two times
in this period automatically and get water scale peeling off, when from element and water tank.
When timer window shows countdown time is “00:00”,TEMP window shows “opl” from “hot”, pls
switch on the manual drain ball valve at this time to drain the water from water tank. When system
detect lack of water for 1 minute,system will switch on the water inlet valve to get water supply to
water tank so as to continue cleaning water scale inside tank for 1 minute and drain water from
manual water ball valve. After finishing cleaning, system quite the cleaning mode automatically.
When TEMP window shows “opl”, if you don't switch on the manual water drain ball valve, the
control panel keeps waiting till the ball valve switch on or press the power on/off to quit cleaning
function.
4. Water tank of steam generator should be cleaned in every 3 months, if the water is hard, suggest
to clean it every 2 months so as to extend the lifespan of heating element and water tank.
5. The cleaning water must be drained through manual water drain ball valve, otherwise, scale will
jam the Auto. water drain valve.