Common troubles trouble shooting methods

To facilitate your use and maintenance of sauna room, the following common troubles trouble 
shooting methods are listed for identification.

Troubles

Causes of troubles

Trouble-shooting methods

The machine does 

not start when 

electrified

1. The fuse is burned.

2. The wire connection terminal 

become loose.

3. Not good contact in the connection 

wire between the controller and the 

steam engine.

1. Change the fuse (on the shell 0.8A/ 250V)

2. Plug tight the wire connection terminal

3. Make sure the steam engine and the 

controller come into good contact

Electricity leakage 

switch

breaks 

automatically

1. The wire connector is dampened 

or damaged.

2. The heating tube breaks

1. Check whether the wire connector is 

dampened or damaged, and dry with 

dryer  if dampened.

2. Change a heating tube.

When the machine is 

started, hot water 

comes out with little 

or no steam

1. The water drainage valve is broken.

1. hange a water drainage valve.

The display screen 

on the control panel 

does not display

1. The power wire is not connected 

well or not in good contact. The 

connection plug between the 

control panel and the electrically-

controlled box becomes loose.

2. Trouble  with  plugboard.

1. Check whether the connection plug 

between the control panel and the 

electrically-controlled box has become 

loose, and whether the power circuitry 

has good contact.

2. change a plugboard.

Water  leakage

1. The water pipe connector becomes 

loose or the pipe breaks

2. Water leakage in the water input 

valve or the water drainage valve

1. Tighten the loose connector, and change 

the broken pipe.

2. Change the water input valve or the 

water drainage valve.

No steam when 

starting the 

machine

1. No electricity.

2. No water.

3. The set temperature is too low

4. Trouble with wire.

1. Check the power supply

2. Check the water input pipe and water 

input valve

3. Reset the temperature

4. Contact the distributor

The steam does not 

come out, the water 

sounds in the 

machine

1. The steam pipe is jammed.

1. Cut power supply to check whether 

the steam pipe is smooth.

The light can not 

be turned on

The display box 

displays normally 

with no steam 

input

1. Too much pressure inside the steam 

engine, so the system breaks for 

heat protection.

2. Wire is broken for heat protection.

1. Check the steam transport pipe and 

restore automatically after heat 

protection becomes cool.

2. Check the heat protection wire to make 

sure the connection is good.

1. The fuse is burned.

2. The light is broken

3. The wire is broken

4. The plug does not have good contact

1. Change the fuse (on the shell 1A/250V)

2. Change a light bulb.

3. Change wire.

4. Cake the contact good.

GEN6-3

Summary of Contents for BAGNODESIGN BAGNOSPA BDD-SPA-GEN6-3-A

Page 1: ...BDD SPA GEN6 3 A BAGNOSPA STEAM GENERATOR 6KW 380V50HZ WITH DIGITAL CONTROL PANEL BLUETOOTH MUSIC BOX 2X SPEAKERS WIFI BOX AND 4 RGB LIGHTS www sanipexgroup com ...

Page 2: ... 5 Electric requirements 6 Installation of the top light 7 Choose your type of machine 8 Maintenance of the steam engine 8 Configuration of steam generator 9 Cleaning of the steam generator 10 Cleaning process 11 Trouble shooting 11 Common troubles trouble shooting methods 12 Ampere Meter 13 Technical parameter 14 Figure Heating element and Power line assemble illustration 15 19 ...

Page 3: ...ich link the controller and the steam generator should be 6 5m 2 The steam generator should not be installed in the steam room 3 Not installed outdoor or in any places that will influence the security of the machine by the environment 4 Do not install it in the frigid loft or any places the water will freeze 5 Do not install it near the burnable and caustic object or chemical coal gas or dope thin...

Page 4: ...g for some time Must take some measures for example using the heat insulation tube to prevent the damage of the hot tube and keep the outlet away from the people 12 The controller must be installed in the steam room please refer to the chapterinstruction of the controller s installation and operation of the manual The steam generator including the controller are comply with the CE and UL certifica...

Page 5: ...esistant to temperature as high as 120 C or higher 4 The horizontal part of the steam pipe should be installed inclining to the steam outlet or in the direction of steam engine Do not bend it in a hape to make sure that the cooled water will not stay in the curved pipe of the steam pipe 5 The shorter the steam pipe the better Try to decrease the number of elbows and avoid abrupt turns Attention Do...

Page 6: ...f effect Inside wall in the steam room Drainpipe 1 2 According to national or local rules the steam engine drainage valve should be equipped with drainpipe The steam engine drains the water by using weight Attention The drainpipe should not incline upwards so as to facilitate the drainage of water Safety valve 1 Safety valve is a piece of safe equipment in order to prevent too much steam pressure ...

Page 7: ...n 200mm 333mm Water inlet Safety valve Steam outlet Manual water drain Water drain provided is limited do not operate on the pipeline and electric equipment arbitrarily as shown in the figure for proportion Caution To avoid damage to the equipment do not connect strong electric current directly to the components To facilitate maintenance keep the steam engine clean If the information Attention ...

Page 8: ...on Installation of the top light Light is available in 12V 220V 230V outputs Before connect to the light please consult with manufacturer to know what voltage the light is so as to avoid generator damage or cause danger If the light output is 12V the power of the light should not be more than 35W othwise transformer will be burned and cause danger If light input is 220v 240V light power should not...

Page 9: ...lls C Celia Heights exceeding 8 FT D Ceramic tile E Glass 2 walls ADD 75 1 Wait for the completion of automatic water discharge after each time of using the steam engine to make sure the water in the tank is discharged completely before cutting off power supply 2 There should not be any leakage or damage among the steam engine steam nozzle components and pipes They should be checked and repaired a...

Page 10: ...ation bracket 3 Circuit board 4 Steam Outlet 5 Pressure relief valve 6 Water fill valve 7 Water drain valve 8 Subsidiary water tank 9 Main water tank 10 Heating Element 105O C Hi limit Transformer 11 12 Terminal block Fuse Earth wire connector 16 17 15 14 13 18 Relay Water level sensor Manual water drain 7 ...

Page 11: ...off when from element and water tank When timer window shows countdown time is 00 00 TEMP window shows opl from hot pls switch on the manual drain ball valve at this time to drain the water from water tank When system detect lack of water for 1 minute system will switch on the water inlet valve to get water supply to water tank so as to continue cleaning water scale inside tank for 1 minute and dr...

Page 12: ...E0 The temperature sensor open circuit Water level sensor failure checking the control cable connection between the control panel to steam generator is loose or not E02 The temperature sensor is Short circuit E03 Signal transfer fault between main panel and sub panel E04 Signal transfer fault between control panel and steam generator E12 E22 E32 E42 water inlet takes over 2 minutes E13 E23 E33 E43...

Page 13: ...hether the connection plug between the control panel and the electrically controlled box has become loose and whether the power circuitry has good contact 2 change a plugboard Water leakage 1 The water pipe connector becomes loose or the pipe breaks 2 Water leakage in the water input valve or the water drainage valve 1 Tighten the loose connector and change the broken pipe 2 Change the water input...

Page 14: ... overflow protection and electricity leakage protection Important The list above is for reference only In actual checking and repairing based on the national and local codes ask professional service personnel to operate Technical parameter Steam Volume ml min Steam Production Time S TYPE GEN6 3 Power Output Potency Error Duration Resistance Steam Pressure Applicable space of the room m3 Water Tank...

Page 15: ...5 20W Color Light 12V 10W G B VCC R Control Panel Music box WIFI box Sub Control Panel Horn2 Horn1 aroma pump Temp2 Temp1 25 c Real time Real time Internal wiring diagram of steam generator 4 5kw 220 240V 1phase Impor tant The parameter listed in the table will be varied from different place and temperature please consultate to the qualificatory designer and architect for the more detailed use ...

Page 16: ...Sub Control Panel Horn2 Horn1 Temp2 Temp1 25 c Real time Real time Internal wiring diagram of steam generator 6kw 220 240V 1phase 1 1 4 2 Black 2 0mm N L 3 2 2 0mm 2 0mm 2 0mm Yellow Red Red Black Red Yellow 2 0mm 2 0mm 2 0mm 2 0mm 2 0mm Light 12V 5 20W Color Light 12V 10W G B VCC R aroma pump 3 4 2 0mm 2 0mm ...

Page 17: ...emp2 Temp1 25 c Real time Real time Internal wiring diagram of steam generator 7 5 9kw 220 240V 1phase 1 1 6 2 Black 2 0mm N L 3 2 2 0mm 2 0mm 2 0mm Yellow Red Red Black Red Yellow 2 0mm 2 0mm 2 0mm 2 0mm 2 0mm Light 12V 5 20W Color Light 12V 10W G B VCC R aroma pump 3 4 2 0mm 2 0mm 5 6 4 5 2 0mm 2 0mm 2 0mm 2 0mm copper short circuit board ...

Page 18: ...ntrol Panel Music box WIFI box Sub Control Panel Horn2 Horn1 Temp2 Temp1 25 c Real time Real time Internal wiring diagram of steam generator 6 9kw 380 415V 3phase 1 2 Black 2 0mm N L1 L2 L3 2 0mm 2 0mm 2 0mm Yellow Red Red Black Red Yellow 2 0mm Light 12V 5 20W Color Light 12V 10W G B VCC R aroma pump 3 4 2 0mm 2 0mm ...

Page 19: ...Note ...

Page 20: ...IND SPA GEN6 3 A 12 21 www sanipexgroup com ...

Reviews: