background image

11

 

SPRAYING

 

1

 

Connect the hose and gun.

 

2

 

Check the electrical service. 

Be sure the electrical service matches the rating 

 

on the machine

s nameplate and that the outlet you use is properly grounded.

 

3

 

Fill the packing nut/wet cup with a few drops of QLube Piston Lubricant.

 

4

 

Flush the sprayer

 

 

a

 

Place the suction tube into the media container.

 

 

b

 

Prime Valve must be 

Open

’ 

in the priming position.

 

 

c

 

When you have ensured that the gun safety latch is engaged, attach tip 

 

 

 

and safety guard.

 

 

d

 

Turn the power switch to the 

On

’ 

position.

 

 

e

 

Allow the pump to prime. After the pump is primed, immediately turn 

 

 

 

the Prime Valve to the 

Closed

’ 

position.

 

 

f

 

Turn Pressure Control Knob to the desired spray pressure.

 

 

g

 

Disengage the gun safety latch and you are ready to spray.

 

 

PRESSURE RELIEF PROCEDURE

 

IMPORTANT! To avoid possible serious body injury, always follow this 

 

procedure whenever your Sanique sprayer is shut off, when checking it, and 

whenever you stop spraying.

 

1

 

Engage the gun safety latch.

 

2

 

Turn the unit off and unplug it from the electrical outlet.

 

3

 

Disengage the gun safety latch and trigger the gun to relieve residual fluid 

 

 

pressure. Hold metal part of the gun in contact with grounded metal pail.

 

4

 

Turn the Priming Valve to the open (priming) position to relieve residual 

 

 

fluid pressure.

 

5

 

Re

-

engage gun safety latch and close Priming Valve. 

 

 

DAILY MAINTENANCE

 

1

 

Keep the displacement pump packing nut/wet cup lubricated with 

 

 

QLube Piston Lubricant at all times. Add a drop of oil with regular use to the 

 

top of the pump. This helps protect the rod and the packings.

 

2

 

Inspect the packing nut daily. If seepage of solution into the packing nut and/

 

or 

 

movement of the piston upward is found (while not spraying), the packing 

 

nut should be tightened enough to stop leakage only, but not any tighter. 

 

 

Over tightening will damage the packings and reduce the packing life.

 

Summary of Contents for S-9

Page 1: ...S 9 SANITISING ELECTRIC SPRAYER USER MANUAL ...

Page 2: ... Balbriggan County Dublin Ireland Declares that the Sanique S 9 Electric Sanitising Sprayer is in compliance with the regulations included in 2006 42 EC Machinery Directive 2014 35 EU Low Voltage Directive 2014 30 EU Electromagnetic Compatibility Directive The standards applied by the manufacturer are EN55014 1 2006 A1 A1 2009 A2 2011 EN55014 1 2017 EN55014 2 2015 EN61000 3 2 2014 EN61000 3 3 2013...

Page 3: ...essary Check all filters are clear of debris clean or replace Check not obstructed with debris contact a Sanique dealer or technician for advice Check not obstructed with debris contact a Sanique dealer or technician for advice 3 Power switch Pressure control knob Supply plug cable Prime valve Air in solution Suction filter Suction tube Lower ball Pump leaking Solution bucket Spray tip Filters Hos...

Page 4: ...MWP 3000 psi SPECIFICATION Motor 1300 watt Weight 34 85 kg complete Warranty 2 years SUPPLIED COMPLETE WITH Sanitising spray gun Sanitising spray lance Gold sanitising atomisation tip 1 4 x 15m textile braided hose assembly PRODUCT CODE 110 volt S9 110 240 volt S9 240 Picture David Henry SprayForm Ltd ...

Page 5: ...5 On off switch Suction tube Pressure control knob SANIQUE S 9 Sanitising spray lance Gold sanitising atomisation tip 15m hose assembly Prime valve Sanitising spray gun ...

Page 6: ...se your Sanique sprayer to rain or wet conditions Do not abuse the cord Never use the cord for carrying pulling or unplugging the sprayer Keep the cord away from heat oil sharp edges or moving parts Replace a damaged cord immediately Damaged or entangled cords increase the risk of electric shock When operating a Sanique sprayer outdoors use an outdoor extension cord suitable for outdoor use Use of...

Page 7: ...d sources of sparks and ignition when spraying WEAR PROTECTIVE EQUIPMENT AT ALL TIMES Always use a respirator eye protection and protective clothing Keep clear of moving parts when starting or operating the sprayer Do not put your fingers into any openings to avoid amputation by moving parts or burns on hot parts When starting the motor maintain a safe distance from moving parts of the equipment E...

Page 8: ... when spraying ALWAYS lock the gun trigger when you stop spraying ALWAYS remove tip from the gun to clean it NEVER try to blow back solution this is not an air powered sprayer ALWAYS follow the PRESSURE RELIEF PROCEDURE before cleaning or removing the spray tip or servicing any system equipment Be sure the equipment safety devices are operating properly before each use Tighten all of the fluid con...

Page 9: ...in use and before servicing or cleaning NEVER remove or modify any part of the gun ALWAYS REMOVE THE SPRAY TIP when cleaning Flush unit at the LOWEST POSSIBLE PRESSURE ALWAYS check operation of all gun safety devices before each use Be very careful when removing the spray tip or hose from the gun A plugged line will contain fluid under pressure If the tip or line is plugged follow the pressure rel...

Page 10: ...er serious bodily injury or property damage Before each use check entire hose for cuts leaks abrasions bulging of the cover or damage or movement of couplings If any of these conditions exist replace the hose immediately NEVER use tape or any device to try to mend the hose as it cannot contain the high pressure fluid NEVER ATTEMPT TO RECOUPLE THE HOSE It is not possible to recouple a high pressure...

Page 11: ...ury always follow this procedure whenever your Sanique sprayer is shut off when checking it and whenever you stop spraying 1 Engage the gun safety latch 2 Turn the unit off and unplug it from the electrical outlet 3 Disengage the gun safety latch and trigger the gun to relieve residual fluid pressure Hold metal part of the gun in contact with grounded metal pail 4 Turn the Priming Valve to the ope...

Page 12: ...12 Suction Filter Quick reference MESH THREAD PRODUCT CODE 15 mesh 1 2 thread QF0535015B 30 mesh 1 2 thread QF0535030B 60 mesh 1 2 thread QF0535060B Fluid Pump ...

Page 13: ...PLETE PACKING KIT INC PARTS 05 06 11 14 16 19 20 1 12 12 008 PACKING SPACER 1 13 12 015 BALL SEAT FASTENER M16xP1 0 1 14 12 011 O RING Ø9 x Ø13 x 2 1 15 12 010 BALL SEAT Ø4xØ13 8x4 1 16 12 012 UPPER CHECK BALL Ø6 35 1 17 12 290 022 DISPLACEMENT PISTON 1 18 12 009 DISC SPRING Ø18xØ34 7x1 3 19 12 013 O RING Ø31 2xØ35 1x1 8 1 20 12 014 O RING 1 21 12 290 028 SEAL SEAT Ø27xØ35 1 22 12 290 030 PACKING ...

Page 14: ...EW M5x35xP0 8 6 48 12 290 050 GEAR HOUSING 1 49 12 290 053 BALL BEARING 1 50 12 290 054 TRUSS HEAD MACHINE SCREW M5x8xP0 8 2 51 12 290 055 CONNECTING ROD 1 52 12 290 056 NEEDLE BEARING 1 53 12 290 057 CRANK GEAR 1 54 12 290 060 BALL BEARING 1 55 1 12 290 062 1 MOTOR UNIT 110V 1 55 2 12 290 062 2 MOTOR UNIT 220V 1 56 12 290 061 SOCKET CAP SCREW M5x12xP0 8 4 57 12 290 064 BRUSH CAP 8x16 2 58 12 290 ...

Page 15: ...0 090 CONTROL BOX 1 78 12 290 094 U BRACKET 2 79 12 290 092 HEX NUT M4xP0 8 6 80 12 290 100 CURRENT PROTECTOR 1 81 12 290 120 SPEED CONTROL 110V 220V 1 82 12 290 119 SOCKET SET SCREW M4x8xP0 7 1 83 12 290 118 SUCTION POWER CONTROL DIAL BLACK 1 84 12 290 115 POWER SWITCH 110V 220V 1 85 12 290 110 WIRE LEAD 1 86 12 290 111 WIRE LEAD 2 87 12 290 108 HEX NUT M3 2 88 12 290 107 LCD DISPLAY 1 89 12 290 ...

Page 16: ... MANIFOLD FILTER 102 12 290 070 FILTER CAP 1 103 12 001 PACKING NUT TOMMY BAR 1 104 12 290 085 HIGH PRESSURE HOSE 1 4 18UNF 1 105 12 290 074 PRESSURE TRANSDUCER 110V 220V 1 106 12 003 OUTPUT NIPPLE PT 1 4 x 1 4 19PF 2 107 12 290 071 FILTER HOUSING 1 108 12 290 075 PRIMING VALVE 1 109 12 016 DRAIN TUBE PT1 8 x0 45M 1 110 12 290 078 SOCKET SET SCREW PT1 4 1 111 12 290 079 HEX NUT M5 P0 8 4 112 12 29...

Page 17: ... HEX BOLT M6x16xP1 0 2 122 12 290 152 FLAT WASHER Ø1 4xØ32x2 2 123 12 290 154 WHEEL 2 124 12 290 155 EXTERNAL CIRCLIP S 19 2 125 12 290 156 FRAME 1 126 12 290 157 FLAT HEAD MACHINE SCREW M4x5xP0 7 4 127 12 290 158 HANDLE MOUNT 2 128 12 290 159 ROLL PIN Ø5x25 2 129 12 290 161 HANDLE 1 ...

Page 18: ...18 ...

Page 19: ...19 ...

Page 20: ...Park Balbriggan County Dublin Ireland K32 KV26 Australia 27 Tatura Avenue Gosford NSW 2250 Email sales sanique co uk www sanique co uk www sanique com au Phone UK 01494 360751 Ireland 1800 714005 Australia 1300 229 757 International 353 1690 3162 ...

Reviews: