Emptying Machine
Prior to the disassembly and cleaning of parts, the
machine must be emptied of product. Use the following
procedures (Steps 1 through 3). If this is first time
operation, disregard these steps.
DO NOT INSERT ANY OBJECTS OR TOOLS INTO
THE MIX INLET HOLE, CARBURETOR TUBE HOLE,
OR FRONT PLATE DISPENSING HOLE WHILE THE
MACHINE IS RUNNING. DAMAGE TO THE
MACHINE OR PERSONAL INJURY MAY RESULT.
1. Remove the carburetor tube (Fig. 3) from the mix
inlet hole and lay in the bottom of the mix pan.
2. Set the control switch (Fig. 2) to the
“CLEANOUT”
position and dispense all product from the freezing
cylinder by pulling downward on the spigot handle (Fig.
4) to empty the machine.
3. Set the control switch to the
“OFF”
(center) position.
Close the spigot handle before proceeding to cleaning.
Disassembly and Cleaning Procedure
1. Fill the machine with cold water and set the control
switch to the
“CLEANOUT”
position.
DO NOT
use
hot water which could damage the machine. Let the
machine agitate briefly and drain the water by pulling
downward on the spigot handle. After the machine is
empty, set the control switch to the
“OFF”
position.
Repeat the above procedure as necessary to make
certain that all product is removed from the machine.
2. Prepare a suitable detergent and water solution at a
temperature of 125
°
to 130
°
F.
DO
NOT
use an
abrasive detergent on any part of the dispenser.
DO NOT USE HOT WATER
DOING SO COULD DAMAGE YOUR MACHINE
3. Fill the mix pan with the cleaning solution. Make
certain that the machine is
“OFF”.
Clean the mix pan
thoroughly with a brush as the solution drains into the
freezing cylinder. Clean the mix inlet tube and the
carburetor tube holes with the brush provided.
Disassembly & Cleaning
CONSULT YOUR LOCAL HEALTH AGENCY FOR CLEANING AND SANITIZING REQUIREMENTS.
This unit does not come presanitized from the factory. Before serving product, the dispenser must be disassembled,
cleaned, lubricated, and sanitized. These instructions are general guidelines only. Cleaning and sanitizing procedures
must conform to local health agency requirements.
WARNING
DISASSEMBLY & CLEANING
Fig. 4
Dispensing Product
PAGE 2
IMPORTANT
O-Ring
Fig. 3
Carburetor Tube
Fig. 2
Control Switch