PRODUCT APPLICATION

C

ONSTRUCTION

The 

Sanitaire

®

Room Air Sanitizer Model RSCS280 consists of:

Germicidal ultraviolet lamps, which deliver germicidal ultraviolet energy in the specific wavelength of 254 
nanometers 

(nm)

, which is highly effective against airborne microbes including: virus, bacteria, and mold spores.

Electronic ballasts.

A polished reflector, whose design and specular aluminum construction, maximizes ultraviolet intensity within the 
exposure chamber.

NEMA 5-15, three-prong plug that operates on 120VAC 60Hz single-phase standard household current is standard 
in most units. The 

Sanitaire

®

is also available for operation on 230VAC 50Hz.

Permanent, washable, electrostatic intake filter, capable of removing airborne particles as small as 5 microns.

A louvered exhaust, which restricts ultraviolet radiation from passing into the room, protecting the room's 
occupants from ultraviolet exposure.

An enclosure and access cover constructed of stainless steel, type 304. Stainless steel construction provides 
strength, durability and lasting value.

An interlock safety switch. The interlock switch interrupts power to the sanitizer, when the access cover is 
removed from the lamp/exposure chamber.

Summary of Contents for RSCS280

Page 1: ...evised January 2011 2003 2011 Atlantic Ultraviolet Corporation ultraviolet com 375 Marcus Boulevard Hauppauge NY 11788 USA 631 273 0500 Fax 631 273 0771 e mail info ultraviolet com Extensive Product Information Available at ...

Page 2: ...r Model RSCS280 Questions that are not specifically answered by these instructions should be directed to the Factory Atlantic Ultraviolet Corporation takes all possible precautions when packaging equipment to prevent damage Carefully inspect and report all damages immediately Do not install damaged equipment Follow all instructions on any labels or tags Carefully inspect all packing materials befo...

Page 3: ...l is used to identify an ULTRAVIOLET LIGHT hazard This symbol pictorial is used to identify the need to wear approved ultraviolet resistant face shield This symbol pictorial is used to identify the need to wear protective gloves SAFETY INSTRUCTIONS WARNING To guard against injury basic safety precautions should be observed including the following 1 Read and follow ALL safety instructions WARNING A...

Page 4: ...perates on 120VAC 60Hz single phase standard household current is standard in most units The Sanitaire is also available for operation on 230VAC 50Hz Permanent washable electrostatic intake filter capable of removing airborne particles as small as 5 microns A louvered exhaust which restricts ultraviolet radiation from passing into the room protecting the room s occupants from ultraviolet exposure ...

Page 5: ...ess steel frame Access to the lamp exposure chamber is gained through the interlocked access door Fixture operation can be monitored from the base panel The operation of the Sanitaire Room Air Sanitizer Model RSCS280 is as follows 1 Air is drawn into the fixture through the the louvered filter panel 2 LED indicator lights provide positive indication of operation of germicidal ultraviolet lamps 3 T...

Page 6: ...ected Germicidal lamps are packed separately to ensure maximum protection for the lamps Keep the lamps aside until ready for installation Carefully inspect all packing materials to prevent the loss of accessories mounting hardware spare parts or instructions Do not discard packing materials until fixture is assembled and check out is complete The Sanitaire Model RSCS280 Room Air Sanitizer includes...

Page 7: ...y from any one of these suspension points unit weight can be found in the equipment specification Avoid using a single cable or chain or other structural element to support more than one suspension point Never attempt to support or suspend this unit on the ceiling tile track system Remember it is the equipment user s responsibility to insure an adequate and safe installation of this equipment and ...

Page 8: ... or maintenance LAMP INSTALLATION REPLACEMENT OR CLEANING WARNING Always disconnect power to the fixture before performing any service or maintenance CAUTION Ultraviolet lamps are easily damaged and may cause injury if broken Exercise care when handling lamps 1 Disconnect power to the fixture 2 Open access door by unlocking the two 2 latches 3 Remove lamps carefully press lamp against the spring l...

Page 9: ... contaminated with heavy grease concentrations wash filter with a detergent solution NOTE Follow all manufacturer s instructions and precautions for handling detergents The filter should be rinsed thoroughly with clean water 6 Shake off any excess water from filter and let dry 7 Replace filter into the housing with airflow direction label pointing into the electrical enclosure 8 Close and re latch...

Page 10: ...nctioning Locate corresponding ballast and replace All germicidal lamps Lamps not installed Install lamps not operating Interlock switch open Confirm access cover is on and latched Interlock switch faulty Replace interlock switch 1 ArmorLite Safety Shield Protective coating applied to Ster L Ray Lamps Insures protection by eliminating the dangers associated with fragments of broken quartz and merc...

Page 11: ...ic Feet per Minute 280 Nominal Fixture Capacityc Cubic Feet per Minute 210 Max Treatment Capacity Cubic Feet per Hour 12 600 Max Room Size 3 Air Changes Hour Cubic Feet 4 200 Max Room Size 4 Air Changes Hour Cubic Feet 3 150 Max Room Size 5 Air Changes Hour Cubic Feet 2 520 Max Room Size 6 Air Changes Hour Cubic Feet 2 100 Dimensions Length Inches 46 5 8 Width Inches 22 1 8 Height Inches 9 7 16 El...

Page 12: ...has been made to determine the patent status of applications illustrated or described in this publi cation Inclusion in this publication of any design or method of use which may be patented is not to be con strued as promoting or sanctioning unauthorized use USER ASSISTANCE Purchased From Date Model Serial No Atlantic Ultraviolet Corporation makes every effort to ensure that the Sanitaire Room Air...

Reviews: