14 / 32
7-3.
Setting the Function
This operation can be performed when the normal mode (output voltage, frequency) is in display.
Each time the Func key is pressed, the pilot lamps
⑤-⑨
blink sequentially, and each function
setting item is displayed on the data display area. The function setting to be displayed when the
Func key is pressed differs according to the operation mode and the amplitude control setting as
follows:
(a)
“A” mode (for the setting other than the setting of (b)
)
Voltage (Frequency)
→
⑥
AUTO
→
⑨
PAT
→
Voltage
(b)
“
A
”
mode (only for setting of 0u:1 and 0L:oF)
Voltage (Frequency)
→
⑥
AUTO
→
⑨
PAT
→
⑤
FUNC
→
Voltage
(c)
“
n
”
mode
Voltage (Frequency)
→
⑥
AUTO
→
⑧
FLOCK
→
⑨
PAT
→
Voltage
To select the setting, press the Freq
▲
key or Freq
▼
key. To execute the setting change, press
the Set key.
When the setting change is completed, the voltage is displayed.
If the process is brought forward to the next item by pressing the Func key without pressing the
Set key during the setting change, the setting will not be changed.
※
If there is no key operation for over 5 min, the voltage is displayed.
(1)AUTO
:
Selects the operation mode.
Data display
Mode
Function
A
A mode
(operation mode)
The feeder operates according to each operation pattern
settings.
The feeder operates according to the amplitude control setting
(0u setting).
The voltage and the frequency themselves cannot be changed.
n
n mode
(adjustment mode)
The feeder operates according to each operation pattern
setting or panel setting.
The feeder operates with VVVF.
Sets the voltage frequency, and adjusts the amplitude.
(2)F-LOCK
:
Sets the frequency lock
Sets whether the frequency should be locked or not in the “n” mode.
(3)PAT
:
Switches the operation pattern.
Px (x=1
-
2): Displays the panel setting. (Setting is enabled only in the
“
n
”
mode.)
outx (x=1
-
2): Displays the operation pattern of the external signal [in3] status.