- 9 -
7.SPECIFICATIONS OF THE MULTI‑ CHANNEL SYSTEM
◎
The detecting element in the probe is divided into 2 to 4 channels, and the removing time is shortened
by limiting the places where the detected needles or iron pieces are straying.
◎
The alarm lamps
⑥
of the main body indicate the detected places for each channel.
◎
For the main body specified with the multi-channel system, the sensitivity adjusting dial
③
,
the alarm lamp
⑥
and the receptacle for the connector
⑦
are increased the numbers equal to the
channel numbers.
For the probe
⑬
, the receptacle
⑯
and the probe cable
⑭
are also increased same as above mentioned.
◎
Even if some channels are not used in the Detector specified with the multi-channel system,
surely connect the probe cable
⑭
to the channels not in use between the main body and the probes.
When all the probe cables
⑭
are not connected, it causes a malfunction.
◎
The main body specified with the multi-channel system and the probe is matching.
Connect the probe having the same number with the main body after confirming each number.
When the main body and the probe having the different numbers each other are connected,
notice that the Detector can not be obtained the original abilities and also it causes malfunction.
Front view of the main body (Example: Specified with 4 channels system)