16
Run the machine where air can be supplied in a stable condition.
Use after-cooler or similar equipment to supply clean air at all times.
Operation Procedures
Provide Air
Check whether air pressure is set at the required
level for main regulator and other regulators as
below.
①
Main Regulator
・・・
0.5MPa
②
Body Rotation Cylinder
・・・
0.3MPa
③
Side Expander Cylinder
・・・
0.2MPa
④
Shoulder Expander Cylinder
・・・
0.2MPa
Body Up/Down Cylinder
Low air pressure can cause a malfunction. If the pressure does not reach its standard level, set the
air pressure properly following the procedure below.
Check Point
Check compressor if the main air pressure does not reach 0.5MPa even after the above adjustment
③
①
②
④
Follow the procedure for proper operation.
Improper operation can cause mechanical failure or injury to operators.
CAUTION
■
How to adjust air pressure
1.
Pull the adjustment knob up.
2.
Turn the knob to adjust air pressure
Clockwise
→
Pressure will increase
Counterclockwise
→
Pressure will decrease
3.
Push the knob down.
Attention!
Summary of Contents for DF-100E-V3
Page 40: ...40 ...
Page 42: ...42 Front Diagram 1 Front Diagram REV 3 ...
Page 44: ...44 Rear Diagram 2 Rear Diagram REV 3 ...
Page 46: ...46 Switch Solenoid Valve Diagram 3 Switch Solenoid Valve Diagram REV 3 315 301 ...
Page 48: ...48 Switch Solenoid Valve Diagram 3 Switch Solenoid Valve Diagram REV 3 315 301 ...
Page 50: ...50 Steam Piping Diagram 4 Steam Piping Diagram REV 3 ...
Page 52: ...52 Cover Diagram 5 Cover Diagram REV 3 513 ...
Page 56: ......
Page 57: ......
Page 58: ......
Page 59: ......
Page 61: ......
Page 62: ...DF 100E V3 Rev 6 2019 1 ...