32
Error No.
1
.
Error Item
2
.
Error Description
3
.
Check Point
E11
1
.
Rotation Start Overtime Error
2
.
Middle sensor
(
SQ02
)
is not detected after more than 4sec. From body rotation start.
3
.
(1) If the red light of the sensor does not turn on when you put a magnet over the rotation
middle sensor, the sensor is in error. Check if the sensor is broken, or the wire connection
is loose or disconnected
(2) Check air pressure. (Body Rotation Cylinder Pressure: 0.3MPa, reference Page 16)
E12
1
.
Rotation End Overtime Error
2
.
End sensor
(
SQ01
)
is not detected after body rotates more than half and more than 4sec.
3
.
(1)When you put a magnet over the rotation end sensor, the red light of the sensor:
①
does light
・・・
it is considered the wrong position of the sensor. Please loosen the
band of it, and find the lighting zone. Please place center of lighting
zone and fix it.
②
doesn’t light
・・・
it is sensor problem. Check if the sensor is broken, or the wire
connection is loose or disconnected
(2) Check air pressure. (Body Rotation Cylinder Pressure: 0.3MPa, reference Page 16)
E20
1
.
Reset Button Error
2
.
Reset Button remains ON more than 15 seconds.
3
.
(1) In the case of keep pushing the button, please release the button. Also, please remove
anything which is pushing the button. If you push the button again, the machine will
return to its original position.
(2) Even if the button is not pushed, if it is showing "E20" error, it is a button problem.
Please check whether the switch is broken or a wire connection is loose or disconnected.
E21
1. Blower Button error
2. Blower Button stays activated if the button is staying pushed by something when the main
power is ON, or the machine is at the original position.
3
.
(1) In the case of keep pushing the button, please release the button. Also, please remove
anything which is pushing the button. If you push the Reset button again, the machine
will return to its original position.
(2) Even if the button is not pushed, if it is showing "E21" error, it is a button problem. Please
check whether the switch is broken or a wire connection is loose or disconnected.
E22
1. Steam Button error
2. Steam Button stays activated if the button is staying pushed by something when the main
power is ON, or the machine is at the original position.
3
.
(1) In the case of keep pushing the button, please release the button. Also, please remove
anything which is pushing the button. If you push the Reset button again, the machine
will return to its original position.
(2) Even if the button is not pushed, if it is showing "E22" error, it is a button problem.
Please check whether the switch is broken or a wire connection is loose or disconnected.
Summary of Contents for DF-100E-V3
Page 40: ...40 ...
Page 42: ...42 Front Diagram 1 Front Diagram REV 3 ...
Page 44: ...44 Rear Diagram 2 Rear Diagram REV 3 ...
Page 46: ...46 Switch Solenoid Valve Diagram 3 Switch Solenoid Valve Diagram REV 3 315 301 ...
Page 48: ...48 Switch Solenoid Valve Diagram 3 Switch Solenoid Valve Diagram REV 3 315 301 ...
Page 50: ...50 Steam Piping Diagram 4 Steam Piping Diagram REV 3 ...
Page 52: ...52 Cover Diagram 5 Cover Diagram REV 3 513 ...
Page 56: ......
Page 57: ......
Page 58: ......
Page 59: ......
Page 61: ......
Page 62: ...DF 100E V3 Rev 6 2019 1 ...