39
Chart 2
“Output Test” List
(
continue from previous page
)
Disp. No.
Output Name
Remark
4C
Neck Clamp Close Solenoid
Solenoid No.18
5A
Front Press Left Transfer Solenoid
Solenoid No.9
5b
Front Press Right Transfer Solenoid
Solenoid No.10
6A
Tuck Press Close Solenoid
Solenoid No.11
6b
Side Expander Open Solenoid
Solenoid No.13
6C
Steam Injection Solenoid
Solenoid No.15
7A
Body Press Close Solenoid
Solenoid No.12
4.
VoL
(
Volume Control
)
・
According to instructions 1 and 2, you will see on the display, please push the
“Enter” button No.4.
・
Dial the “Setting & Select” knob No.5, the volume number is shown on the display
(reference Chart 3), so select the volume you want to change. Press the “Enter” button
No.4, current volume number will be shown on the display.
・
Dial the “Setting & Select” knob and change the timer. Then press the “Enter” button
No.4 to confirm the set up.
Chart 3
“Volume Control” List
Disp.
No.
Details
Standard Set
Timer
V 1
To control brake air supply timer for front press transfer to left
0.28 sec.
(
Max. 1.3 sec.
)
V 2
To control brake air supply timer for front press transfer to right
0.25 sec.
(
Max. 1.3 sec.
)
V 3
To control Sleeve Arm tension to soften.
0.035 sec.
(
Max. 0.2 sec.
)
V 4
To control blower motor start timing after body press start
3.25 sec.
(
Max. 5.1sec.
)
V 5
To control side expander open timer after second foot pedal.
1.35 sec.
(
Max. 3.0 sec.
)
V 6
To control timing between body press start and sleeve arm start
to open
1.6 sec.
Max. 3.0 sec.
)
V 7
To control timing between body press start and tuck press start
to close
2.3 sec.
(
Max 3.0 sec.
)
V 8
To control tuck press time.
32sec.
(
Max. 32 sec.
)
V 9
To control sleeve arm opening time from close position when size
adjustment button is OFF.
0.4 sec.
(
Max. 1.5 sec,
)
V 10
To control timing from sleeve arm completely down and starting
“V3” function
3.0 sec.
(
Max. 5.0 sec.
)
V 11
To control sleeve arm to close before its completely down after
complete press operation.
0.15 sec.
(
Max. 0.3 sec.
)
V 12
(Not in Use)
V 13
To control Steam Injection start timing after body press start
4.25 sec.
(
Max. 5.0 sec.
)
Summary of Contents for LP-570E-V2
Page 54: ...54 Motor Operation Diagram 1 Motor Operation Diagram REV 4...
Page 56: ...56 Air Piping 1 2 Air Piping 1 REV 3 3DLP570E V2 052 2...
Page 58: ...58 Air Piping 2 3 Air Piping 2 REV 3 3DLP550J V2 053 6...
Page 60: ...60 Air Piping 3 4 Air Piping 3 REV 3 3DLP550J V2 054 6...
Page 62: ...62 Steam Piping 5 Steam Piping REV 3 3DLP570E V2 055 1...
Page 64: ...64 Control Box Switch Diagram 6 Control Box Switch Diagram REV 3 3DLP550J V2 056 6...
Page 66: ...66 Cover Diagram 7 Cover Diagram REV 3 3DLP570E V2 057 3...
Page 69: ......
Page 70: ......
Page 71: ......
Page 72: ......
Page 73: ......
Page 74: ......
Page 75: ......
Page 76: ...LP 570E V2X Rev 6 2019 6 1 2 B...