45
Error
No.
1. Error Item
2. Error Description
3. Check Point
E35
1. Left Cuff Clamp Button Error
2. (1) Cuff Clamp Button
keeps
activated if the button is kept pressing by something when the
main power is ON, or the machine is at the original position.
(2) Cuff Clamp Button is kept pressing for more than 5 seconds even if you release the button.
3. (1) In the case of a button being pushed by something, the error will be released if you release it from
the button and push the reset button.
(2)
Even if it is not pressed button, if it is showing “E35” error, it is a switch problem.
Please check whether the switch is broken or a wire connection is loose or
disconnected.
E36
1. Press Start Button Error
2. Press Start Button
keeps
activated when the main power is ON, or the machine is at the original
position.
3. (1) In the case of a button being pushed by something, the error will be released if you release it from
the button and push the reset button.
(2)
Even if it is a not pressed button, if it is showing “E36” error, it is a switch problem.
Please check whether switch is broken or a wire connection is loose or disconnected.
E37
1. Short Button Error
2. Short Button
keeps
activated when the main power is ON.
3. (1) In the case of a button being pushed by something, error will be released if you release the button
and push the reset button.
(2)
Even if it is not a pressed button, if it is showing “E37” error, it is a switch problem.
Please check whether switch is broken or a wire connection is loose or disconnected.
E38
1. Foot Pedal Error
2. Foot Pedal keeps
activated
when the main power is ON, or machine is at the original
position.
3. (1) In the case of keep pushing button, please release the pedal. Also, please remove
anything which is pushing the pedal. If you press the Reset button again, the
machine will return to its original position.
(2) Even if the button is not pressed, if it is showing “E38” error, it is a switch problem.
Please check whether the switch is broken or a wire connection is loose or
disconnected.
E39
1. Shoulder Press / Slide Start Button Error
2. (1) Shoulder Press / Slide Start Button
keeps
activated by something when the main power is
ON, or the machine is at the original position.
(2) Shoulder Press / Slide Start Button is kept pressing for more than 5 seconds even if you release the
button.
3. (1) In the case of a button being pushed by something, the error will be released if you release it from
the button and push the reset button.
(2)
Even if it is not pressed button, if it is showing “E39” error, it is a switch problem.
Please check whether switch is broken or a wire connection is loose or disconnected.
Summary of Contents for LP-570E-V2
Page 54: ...54 Motor Operation Diagram 1 Motor Operation Diagram REV 4...
Page 56: ...56 Air Piping 1 2 Air Piping 1 REV 3 3DLP570E V2 052 2...
Page 58: ...58 Air Piping 2 3 Air Piping 2 REV 3 3DLP550J V2 053 6...
Page 60: ...60 Air Piping 3 4 Air Piping 3 REV 3 3DLP550J V2 054 6...
Page 62: ...62 Steam Piping 5 Steam Piping REV 3 3DLP570E V2 055 1...
Page 64: ...64 Control Box Switch Diagram 6 Control Box Switch Diagram REV 3 3DLP550J V2 056 6...
Page 66: ...66 Cover Diagram 7 Cover Diagram REV 3 3DLP570E V2 057 3...
Page 69: ......
Page 70: ......
Page 71: ......
Page 72: ......
Page 73: ......
Page 74: ......
Page 75: ......
Page 76: ...LP 570E V2X Rev 6 2019 6 1 2 B...