46
Error
No.
1. Error Item
2. Error Description
3. Check Point
E40
1.Shoulder Press Close Sensor Error
2. It is not detected Shoulder Press Close sensor (SQ06) even if press is activated.
3. (1) When you touch magnet to sensor at the rod side of cylinder, the red light of sensor
…
①
does light
・・・
it is considered wrong position of sensor. Please loosen the band of it,
and find lighting zone. Please place center of lighting zone and fix it.
②
doesn
’
t light
・・・
it is sensor problem. Check sensor is broken, or wire
connection (such as looseness or disconnection).
(2) Check air pressure. (Main Pressure: 0.6MPa, reference Page 15)
E41
1. Shoulder Press Open Sensor Error
2. It is not detected Shoulder Press Open sensor (SQ07) even if press is activated.
3. (1)When you touch magnet to sensor at the head side of cylinder, the red light of sensor
…
①
does light
・・・
it is considered wrong position of sensor. Please loosen the band of it,
and find lighting zone. Please place center of lighting zone and fix it.
②
doesn
’
t light
・・・
it is sensor problem. Check sensor is broken, or wire
connection (such as looseness or disconnection).
(2) Check air pressure. (Main Pressure: 0.6MPa, reference Page 15)
E42
1. Long Button Error
2. Long Button
keeps
activated when the main power is ON.
3. (1) In the case of a button being pushed by something, the error will be released if you release the
button and push the reset button.
(2)
Even if it is not a pressed button, if it is showing “E42” error, it is a switch problem.
Please check whether switch is broken or a wire connection is loose or disconnected.
E49
1. Front Press Close Sensor Error
2. It is not detected Front Press Close sensor (SQ09) even if press is activated.
3. (1)When you touch magnet to sensor at the rod side of cylinder, the red light of sensor
…
①
does light
・・・
it is considered wrong position of sensor. Please loosen the band of it,
and find lighting zone. Please place center of lighting zone and fix it.
②
doesn
’
t light
・・・
it is sensor problem. Check sensor is broken, or wire connection
(such as looseness or disconnection).
(2) Check air pressure. (Main Pressure: 0.6MPa, reference Page 15)
E50
1. Front Press Original Position Sensor Error
2. It is not detected Front Press Original Position sensor (SQ13) even if press head is at
position.
3. (1)When you touch magnet to sensor at the head side (right) of cylinder, the red light of
sensor
①
does light
・・・
it is considered wrong position of sensor. Please loosen the band of it,
and find lighting zone. Please place center of lighting zone and fix it.
②
doesn
’
t light
・・・
it is sensor problem. Check sensor is broken, or wire connection
(such as looseness or disconnection).
(2) Check air pressure. (Main Pressure: 0.3MPa, reference Page 15)
Summary of Contents for LP-570E-V2
Page 54: ...54 Motor Operation Diagram 1 Motor Operation Diagram REV 4...
Page 56: ...56 Air Piping 1 2 Air Piping 1 REV 3 3DLP570E V2 052 2...
Page 58: ...58 Air Piping 2 3 Air Piping 2 REV 3 3DLP550J V2 053 6...
Page 60: ...60 Air Piping 3 4 Air Piping 3 REV 3 3DLP550J V2 054 6...
Page 62: ...62 Steam Piping 5 Steam Piping REV 3 3DLP570E V2 055 1...
Page 64: ...64 Control Box Switch Diagram 6 Control Box Switch Diagram REV 3 3DLP550J V2 056 6...
Page 66: ...66 Cover Diagram 7 Cover Diagram REV 3 3DLP570E V2 057 3...
Page 69: ......
Page 70: ......
Page 71: ......
Page 72: ......
Page 73: ......
Page 74: ......
Page 75: ......
Page 76: ...LP 570E V2X Rev 6 2019 6 1 2 B...