49
Check Item (Daily)
1.
Air Pressure
:
Figure-1
Please make sure if the air pressure gauge at the regulator is at the standard level. See “Main Devices”
and “Operation Procedure* Provide Air” in the Instruction Manual for the installation location and
standard pressure level.
[
How to Adjust Pressure
]
①
Pull the adjustment knob up
②
Turn the knob to adjust air pressure
・
Clockwise
→
Pressure will increase
・
Counterclockwise
→
Pressure will decrease
③
Pull the knob down
2.
Regulator/Mist Separator
:
Figure-2
Check if the automatic drain function works properly at the Regulator/Mist Separator. The drain is
automatically discharged when the quantity of the drain reaches over half of the drain case.
If the drain cannot be discharged even after over half of the drain case is filled, it might malfunction.
Turn the dial under the Regulator to the left and let the drain discharge.
Adjustment
②
Combination
Regulator
Adjustment
①
Adjustment
③
(Pressure increases)
(Pressure decreases)
Figure-1
Drain Outlet
Combination
Figure-2
Drain Discharge Level
Summary of Contents for LP-570E-V2
Page 54: ...54 Motor Operation Diagram 1 Motor Operation Diagram REV 4...
Page 56: ...56 Air Piping 1 2 Air Piping 1 REV 3 3DLP570E V2 052 2...
Page 58: ...58 Air Piping 2 3 Air Piping 2 REV 3 3DLP550J V2 053 6...
Page 60: ...60 Air Piping 3 4 Air Piping 3 REV 3 3DLP550J V2 054 6...
Page 62: ...62 Steam Piping 5 Steam Piping REV 3 3DLP570E V2 055 1...
Page 64: ...64 Control Box Switch Diagram 6 Control Box Switch Diagram REV 3 3DLP550J V2 056 6...
Page 66: ...66 Cover Diagram 7 Cover Diagram REV 3 3DLP570E V2 057 3...
Page 69: ......
Page 70: ......
Page 71: ......
Page 72: ......
Page 73: ......
Page 74: ......
Page 75: ......
Page 76: ...LP 570E V2X Rev 6 2019 6 1 2 B...