background image

 

 

 

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

PALERT 

WEB 
CONFIGURATION

 

 

USER MANUA 

Version 2 
17/11/2017

 

Jenlogix Ltd 
Unit 11,250 Marua Rd 
Mt Wellington,Auckland 1051 
PO Box 87131 Meadowbank 
Auckland 1742 
New Zealand 
Phone:+64 9 579 6339 
Fax:+64 9 820 9447 
www.jenlogix.co.nz

 

Status:Released 

Summary of Contents for Palert

Page 1: ...ION USER MANUA Version 2 17 11 2017 Jenlogix Ltd Unit 11 250 Marua Rd Mt Wellington Auckland 1051 PO Box 87131 Meadowbank Auckland 1742 New Zealand Phone 64 9 579 6339 Fax 64 9 820 9447 www jenlogix c...

Page 2: ...chnical inaccuracies or typographical errors CONTENTS 01 PALERT SYSTEMS 2 1 1 PASSWORDS 2 02 WEB INTERFACE FOR SOFTWARE CONFIGURATION 3 2 1 CONNECTION SETTINGS 3 03 WEB INTERFACE 5 3 1 LOGIN 5 3 2 NET...

Page 3: ...since it was created Revision Date Author Comments 0 1 17 11 2017 VP SP BH Merge of various docs REFERENCES AND SUPPORTING DOCUMENTS Document Date Document Stored as JENLOGIXQNAPP1 Jenlogix Supplier B...

Page 4: ...er Palert netRelay Palert netTower Palert netSPeaker This manual shows the configuration options for all these devices Refer to the individual Setup guides for hardware and other information specific...

Page 5: ...from a local PC Laptop it is necessary to change the PC network IP address to match the subnet of the unit To find the IP address of the unit press the internal control button see Control Button The...

Page 6: ...U S E R M A N U A L Version 2 17 11 2017 Jenlogix 2017 Jenlogix Page 4 of 40 Click Local Area Connection then Properties IPv4 Change your computer IP subnet E g 192 168 255 xxx 3 4...

Page 7: ...erface Open a web browser and enter the Unit IP on the address bar This is found as above Login to pi account Language Chinese or English Default User pi Default Password 1111 There is also an Admin u...

Page 8: ...ended to keep the DHCP off if possible if you wish to connect using other utilities Otherwise the IP address will need to be found before retrieving any data and do any changes But it is not essential...

Page 9: ...U S E R M A N U A L Version 2 17 11 2017 Jenlogix 2017 Jenlogix Page 7 of 40 3 3 RESET PASSWORD To change the web password go to edit password tab and set as required...

Page 10: ...ge 8 of 40 3 4 SET THE NTP SERVER This is required to ensure the time stamp is kept correct If the unit cannot connect to an NTP server i e is not on a network then the timestamp of the data will be b...

Page 11: ...U S E R M A N U A L Version 2 17 11 2017 Jenlogix 2017 Jenlogix Page 9 of 40 DNS settings...

Page 12: ...U S E R M A N U A L Version 2 17 11 2017 Jenlogix 2017 Jenlogix Page 10 of 40 3 5 SET INFORMATION TAB To change S N of Unit use this tab this should not need to be changed unless directed...

Page 13: ...U S E R M A N U A L Version 2 17 11 2017 Jenlogix 2017 Jenlogix Page 11 of 40 3 6 FILE TAB This enables file upload and download of configuration information preloading of settings...

Page 14: ...Jenlogix 2017 Jenlogix Page 12 of 40 3 7 DOWNLOADING EVENT FILES For any event the system will store a csv file containing details of movement in the 3 axes To copy any file go to Manage Events tab t...

Page 15: ...U S E R M A N U A L Version 2 17 11 2017 Jenlogix 2017 Jenlogix Page 13 of 40 3 8 RECORD FILES To view event files directly from web interface 3 9 STREAMING To check waveforms for all three axis...

Page 16: ...U S E R M A N U A L Version 2 17 11 2017 Jenlogix 2017 Jenlogix Page 14 of 40 3 10 PARAMETERS SETTING TAB The Parameters menu option is only available to the admin user...

Page 17: ...rther information on many of these parameters 3 11 1 EARLY WARNING PARAMETERS PALERT_LOCAL_MODE SERIAL_NO Serial number of the unit normally should not be changed LCD_BACK_LIGHT_SECOND 15 SERVER_IP Se...

Page 18: ...EAMING_IN_MSEC Millisecond stream default 1000 SAMPLING_RATE Sampling rate 50 100 200 sps VECTOR_INTENSITY YES NO SPS_CH0 Samples per second Channel 0 Default 50 SPS_CH1 Samples per second Channel 1 D...

Page 19: ...shold of STA LTA seconds STA_LTA_THRESHOLD STA LTA ration trigger threshold STA_LTA_STOP_THRESHOLD Time window of LTA seconds STA_LTA_EVENT_TIME STA LTA trigger duration seconds STA_LTA_RELAY1 RELAY1...

Page 20: ...ff CPU_STATUS_DISPLAY_INTERVAL Length of time between CPU status displays WALL_MOUNT Is unit Wall mounted RING_SECONDS 30 RING_CHANNELS 3 RING_FILTERED NO WIRELESS_LAN_ENABLE NO NTP_RESET RESET_TH 2 E...

Page 21: ...EQ_STEP 0 1 G_START 28 D_START 0 7 F_START 4 5 MASS_KG 0 011 DIN_VIBRATION FFT_SECONDS 10 STRUCTURE_TYPE 2 DISPLAY_ON_LCD YES GEO_PHONE NO RECORD YES RECORD_ALWAYS YES WARNING_DB 6 PGA_RELAY NO RELAY1...

Page 22: ...0 of 40 3 11 2 OTHER PARAMETERS BACKUP_PROGRAM YES SWITCH_UNLOCK_CODE Key unlock code ADMIN_SERVER_IP Future use MMI_INTENSITY NO BROADCAST_PORT Future use LCD_TITLE Title on LCD POWER_OFF_SWITCH_EXIS...

Page 23: ...one will be the main Palert out of M Starting from 0 M N WHERE N OUT OF M N out of M Palerts here add value for N M WHERE N OUT OF M N out of M Palerts here add value for M N OUT OF M IN SECOND Accep...

Page 24: ...TUDE Latitude of Unit degrees HEIGHT Elevation of Unit degrees SITE EFFECT To handle the site geophysics effect This is a number that is generated from historic data and defaults to 1 931 It should no...

Page 25: ...me 1380 60 23 or 11pm EEWS DAY VOICE INTENSITY Regional Day speech warning alert intensity threshold EEWS NIGHT VOICE INTENSITY Regional warning voice alerts night intensity threshold DAY VOICEALARM I...

Page 26: ...P protocol It is designed for connections with remote locations where a small code footprint is required or the network bandwidth is limited In addition to local warnings and regional warnings Palert...

Page 27: ...power key for 4 Seconds enters test mode 0 RELAY_HOLD_SECOND 5570590 5570590 0x0055001e 55 85 gal 1e 30 seconds PLAY_FILE 2 wav Play audio files2 wav RELAY2 ON Drive RELAY2 STAGE 1 Mode 1 SWITCH_SECON...

Page 28: ...ancel the alarm PLAY_FILE eewsCancel wav Plays audio files eewsCancel wav 3 11 8 FTP CONFIG Unit firmware update function generally do not need to modify IP FTP Server IP PORT FTP Server port USER FTP...

Page 29: ...the relay RELAY_RESET_BY_MANUAL Reset relay manually SINGLE_RELAY_MODE Event trigger after a relay trigger 3 11 11 API API_CONFIG setup API parameter EARTHQUAKE_FALLING_API After the end of the event...

Page 30: ...A L Version 2 17 11 2017 Jenlogix 2017 Jenlogix Page 28 of 40 3 11 13 UPLOAD AN EVENT RECORD BROADCAST_PORT_INTERFACE If it s set the device will be through UDP Broadcast transmission port area messag...

Page 31: ...ion requires using terminal access This can be done with product like Putty Instructions as below 4 1 INSTALL PUTTY OR SIMILAR ON A LAPTOP http www putty org Change laptop IP to 192 168 255 xx 20 as e...

Page 32: ...GE Using PUTTY login to the unit with the pi 1111 default user and password At prompt type passwd Enter existing password Then enter new password twice This will need to be failry complex and not simi...

Page 33: ...sing same user name password as described in section 4 above with port 22 Then go to folder Desktop vAlert8 bin Voice alarms are stored in uncompressed wav format Optional default voices for Chinese a...

Page 34: ...ending how many seconds the button is pressed Display IP Address Voice Test Reset EEWS Alarm Cancel Reset Network Reload by key Test Mode Config Status N A FTP update N A Test Mode N A N A Shutdown 6...

Page 35: ...U S E R M A N U A L Version 2 17 11 2017 Jenlogix 2017 Jenlogix Page 33 of 40 6 3 OPTIONS Press and hold the control button 2 to perform the functions below CUBE PALERT PX 01...

Page 36: ...U S E R M A N U A L Version 2 17 11 2017 Jenlogix 2017 Jenlogix Page 34 of 40 6 3 1 HOLD FOR 1 SECONDS DISPLAY IP 6 3 2HOLD FOR 2 SEC RESTART NTP...

Page 37: ...U S E R M A N U A L Version 2 17 11 2017 Jenlogix 2017 Jenlogix Page 35 of 40 6 3 3 HOLD FOR 3 SEC RESET WARNING 6 3 4 OLD FOR 4 SEC RELOAD CONFIGURATION PARAMETERS...

Page 38: ...U A L Version 2 17 11 2017 Jenlogix 2017 Jenlogix Page 36 of 40 6 3 5 HOLD FOR 5 SECS TEST MODE CONFIG STATU 6 3 6 HOLD FOR 6 SECS No function 6 3 7 OLD FOR 7 SECS USE FTP UPDATE 6 3 8 HOLD FOR 8 SEC...

Page 39: ...for 6 seconds test mode 1 on site warning test level 3 Press the button for 8 seconds test mode 2 on site warning test level 4 Press the button for 3 seconds test mode 3 cancel Press 10 seconds to te...

Page 40: ...can be changed using a Modbus client for those that are not listed in the configuration file 7 1 AO REGISTERS UNIT Modbus AO Address Mapping Table 40XXX Register Description Note 113 Data Changed 0x01...

Page 41: ...stem time in month 108 System time in day 109 System time weekday 110 System time in hour 111 System time in minute 112 System time in second 113 Event time in year 114 Event time in month 115 Event t...

Page 42: ...oStatus16_31 500 UNIT serial number 1 4 v2 07 501 UNIT serial number 2 4 502 UNIT serial number 3 4 503 UNIT serial number 4 4 600 Rain fall in counts within 1 minutes 601 Rain fall in counts within 1...