Page 21
Safety cut-out
If the battery fails to reach a certain voltage value within a pre-determined
time, the charger automatically cuts out
What to do after a safety cut-out:
1. Unplug the charger from the mains
2. Disconnect the charger from the battery
3. Investigate the reason for the safety cut-out
Technical data
Mains voltage (50/60 Hz, +/-15 %)
100-230 V AC
Open-circuit power consumption
max. 1,5 W
Rated power output
48 W
Charging voltage
24 V DC
Arithmetic charging current with 230 V / 50 Hz
2,0 A
Degree of protection
IP30
Time until safety cut-out
4,5 h
The charger has been function tested
-
in a temperature range from -20°C to +50°C
-
in atmospheric humidity ranging from 5-85 %
Component specification: Climatic category B
5.1.4 Safety rules
Utilisation for intended purpose only
-
This battery charger is designed to charge
lead storage batteries filled with liquid,
gel and AGM (absorbed glass mat) electrolytes
only.
- This battery charger should never be used to charge NiCd and NiMH batteries and
primarcy cells.
Only use the unit if
- it is protected from direct sunlight and kept dry, and
- cooling air can flow through the ventilation slots unhindered.
CE marking
This battery charger meets the fundamental requirements of the Low-Voltage and
Electromagnetic Compatibility Directive and is thus CE-marked.