Step Fogging times and consumption (low / high contamination)
–
not applicable for
Afnor T72-281 (2014)
Room
Size
Fogging time/consumption
normal contamination (8ml/m
3
)
Fogging time/consumption
high contamination (16ml/m
3
)
m
3
Step1
Step2
Step3
ml:
Step1
Step2
Step3
ml:
10
1/30
2/15
0/0
99 ml
2/30
4/15
0/0
198 ml
20
2/30
3/15
0/0
165 ml
4/30
6/15
0/0
330 ml
30
3/30
4/15
0/0
231 ml
6/30
8/15
0/0
462 ml
40
5/30
5/15
0/0
330 ml
10/30
10/15
0/0
660 ml
50
4/30
4/15
4/0
396 ml
8/30
8/15
8/0
792 ml
60
5/30
5/15
5/0
495 ml
10/30
10/15
10/0
990 ml
70
5/30
6/15
6/0
561 ml
10/30
12/15
12/0
1122 ml
80
6/30
6/30
7/0
627 ml
12/30
12/30
14/0
1254 ml
90
7/30
7/30
8/0
726 ml
14/30
14/30
16/0
1452 ml
100
8/30
8/30
8/0
792 ml
16/30
16/30
16/0
1584 ml
150
12/30
12/30
12/0
1188 ml
24/30
24/30
24/0
2376 ml
200
16/30
16/15
16/0
1584 ml
32/30
32/15
32/0
3168 ml
250
20/30
20/15
20/0
1980 ml
40/30
40/15
40/0
3960ml
300
24/30
24/15
25/0
2409 ml
350
28/30
28/15
29/0
2805 ml
400
32/30
32/15
33/0
3201 ml
450
36/30
36/15
37/0
3597 ml
500
40/30
40/15
40/0
3960 ml
550
44/30
44/15
44/0
4356 ml
•
Step Fogging times and consumption meeting the norm
Afnor T72-281 (2014) with Sanosil S015
For details please refer to the Sanosil test reports T319, T320 and T321
Room
Size
Fogging time/consumption according the norm
Afnor T72-281 (2014), valid for Sanosil S015 for:
bacteria’s, yeasts, molds
(28ml/m
3
)
Fogging time/consumption according the norm
Afnor T72-281 (2014), valid for Sanosil S015 for:
bacterias, yeasts, molds, spores
(33ml/m
3
)
m
3
Step1
Step2
Step3
ml:
Step1
Step2
Step3
ml:
10
4/30
2/30
2/30
277 ml
5/60
3/60
2/60
330 ml
20
8/30
4/30
4/30
554 ml
10/60
6/60
4/60
660 ml
30
12/30
6/30
6/30
831 ml
15/60
9/60
6/60
990 ml
40
16/30
8/30
8/30
1108 ml
20/60
12/60
8/60
1320 ml
50
20/30
10/30
10/30
1386 ml
25/60
15/60
10/60
1650 ml
60
24/30
12/30
12/30
1663 ml
30/60
18/60
12/60
1980 ml
70
28/30
14/30
14/30
1940 ml
35/60
21/60
14/60
2310 ml
80
32/30
16/30
16/30
2217 ml
40/60
24/60
16/60
2640 ml
90
36/30
18/30
18/30
2495 ml
45/60
27/60
18/60
2970 ml
100
40/30
20/30
20/30
2772 ml
50/60
30/60
20/60
3300 ml
110
44/30
22/30
22/30
3049 ml
55/60
33/60
22/60
3630 ml
120
48/30
24/30
24/30
3326 ml
60/60
36/60
24/60
3960 ml
130
52/30
26/30
26/30
3603 ml
65/60
39/60
26/60
4290 ml
140
56/30
28/30
28/30
3880 ml
150
60/30
30/30
30/30
4158 ml
160
64/30
32/30
32/30
4435 ml
Check temperature of the room, to be between 15 to 35 °C.
Check relative humidity of the room, to be max. 45 % rH. / (before fogging)
at higher humidity, the humidity must be lowered before start-up or a lower dosage of the active substance must be selected.