Sanosil Q-Jet Superior
26
5.12
Program Pulse
(without and with timer settings)
Pulse one time disinfection process. The disinfection process is slowed down and lasts 50% longer.
During 30 seconds, the interval liquid dosing is activated followed by a 15 second pause in which no liquid dosing
takes place, but the turbine continues to run and generates an air flow.
The advantage of the pulse program is a slower liquid dosing into the room which is especially advantageous in
smaller rooms or in rooms with increased humidity.
Please read and follow important safety directions on page 6 before use!
Settings
„program Pulse“
(without timer)
•
Starting on main screen, press
„F2“
or icon
„Settings“
to input
users‘
settings
•
Select desired program type (Pulse)
Oder
•
Note for users using a printer (type of printer page 42).
Please note: After every operation with the Sanosil Q-Jet
a
printout can be printed by pressing the “reprint” button.
•
Touch fields:
Volume/Concentration/Code Charge/Typology to
open the respective keyboard screen.
Input or change values according to your needs and confirm your
inputs with Enter.
- Volume:
room volume in m
3
(length x width x height)
-
Concentration:
dosage desired per m
3
(usually 8, 12, 16ml)
-
Code Charge:
Definition of disinfection liquid
- Typology:
Name of room (e.g. surgery room 2)
•
After all required data are entered select escape “ESC” to
return to the main screen (if you would like to set a timer please continue on page 28):
•
Check on main screen all pre-set data
(no error message (red bar) = device ready)
e.g. displayed on this screen : ALR-
01 „Liquid
Level“ Please see
below, chapter 7.2. to
remove errors
F2