Sanosil Q-Jet Superior
9
4.
Getting Started and Operating Instructions
4.1
Warning
WARNING
Risk of Injuries!
This device nebulizes chemical substances!
Do not inhale these substances, always wear safety equipment when filling/emptying tank and pay
attention to optical and acoustic warning signals.
Read carefully all indications stated on the safety data sheet of the disinfection liquid and fully comply
with them!
Make sure
NOBODY
is in the room and to affix a warning board on the entrance door when
the system starts!
4.2
Room Preparation and positioning of device
4.2.1 Room Preparation
•
Close windows
•
Pull back and secure all room dividing curtains
•
If possible turn off, then cover and seal all air handling units, heaters and smoke detectors
•
Check relative humidity of the room, to be max. 45 % rH. / (before fogging) at higher humidity, the humidity must be
lowered before start-up or a lower dosage of the active substance must be selected.
•
Check temperature of the room, to be between 15 to 35 °C.
•
Affix warning board on entrance door. Seal bottom of room door after exiting (e.g. with large
painters’
tape)
4.2.2
Positioning of the device
•
Avoid direction of air flow towards entrance door and air conditioning units.
•
Position the device in a corner of the room (minimum rear distance to wall 30 cm to enable intake of room air).
•
Place device on a stable, flat, dust-free, none slippery, horizontal surface which can appropriately support its weight.
•
Minimum distance between Q-Jet Compact 2+ and closest object (wall, door etc.): 6 m
•
Point nozzle towards center of the room.
•
Do not point nozzle towards smoke detectors and check with facility management to take appropriate measures to
avoid any activation of the detector systems during nebulization process.
Minimum distance between device and next object: 6 m