background image

ENGLISH – ENGLISH – ENGLISH – ENGLISH – ENGLISH    – ENGLISH - 

Introduction  

1.

Before you unpack the shower, you check the packaging for damage. Later complaints will not be recognized. Before

assembling, all parts for damage and completeness are checked. In case of problems contact the seller and us time and
you will get a satisfactory answer.

2.

For installation the following tools is required: drill, screwdriver, spirit level, tape measure, pen, ring wrench

.

3

. With embossed glass or frosted glass is to be noted is that the smooth side mounted to the inside.

4.

It is all factory-fitted shower room for testing purposes, connected, tested and packaged.

5

. Place the shower tray and using adjustable feet, so set that no water remains in the shower tray.

IMPORTANT: stress test. Subsequent complaints are excluded.

6.

The assembly should be conducted only by authoritarian specialist firms (eg plumber), otherwise it will void the

warranty. (See also note for connection of water and electricity)

7.

It is observed the enclosed assembly instructions and all parts must be additionally sealed against each other with

sanitary silicone (silicone) Leak test. In addition, need to be checked all the screws, hose clamps, etc. to its strength and
tightness. It might have come loose due to the transport something.

INSTALLATION - MAINTENANCE - WARRANTY - SECURITY - TERMS OF USE 

TECHNICAL DATA:

  

Conection

 

220 V / 50 Hz

, Control 

12 V 

Water pressure  

1 – 3 bar, max. 60° WW, max. 9° DH 

1.

Water installation:

(On site) The connection may be performed by an officially licensed installation companies. The installation 
requirements of the local water company and the provisions of DIN 1988 are to be observed strictly. For the sewer 
connection is to provide for a trap. 
Attention: No rigid pipe connections between Fertigduschen and water - risk of breakage! This line must be secured 
by a Rohrunterbrecher type A2 according to DIN 1988. The connections must be flexible, allowing an unobstructed 
maintenance or service at any time. 
The water temperature of the water, which flows through the faucets and showers can be max.    C..

°

60  The water 

pressure can be max. 4 bar. 
In general, observed for the water installation with all legal requirements

   

2.

WATER 

CONDUCT:  (On site) 

 40mm (

 50mm)

There must be a flexible, extensible intermediate (50 cm) between the siphon and sewer connection be installed so that a push
back for maintenance or service is possible.

3.

Electrical 

installation   

(On site) The electronic connection may be performed only by an officially licensed electrical company.

The installation requirements of local utility companies and the provisions of DIN 57100 or
VDE 0100 Part 701 must be strictly observed. The cable (sheathed cable H05VV-f3G2, 5 YMM-J 3x2, 5 mm ² up to 3500 watts)
must have an earth leakage circuit breaker (at least 25 A 230/400 V ~ Auslösenennstrom I = 0.03 A are held) and a circuit breaker
IN = 16 A or 25 A U-type (in Austria: IN = 13 A 16 or A C-Type will be protected). Similarly, this circuit must be switched off with an
all-pole switch with at least 3 mm contact gap. (must be in the protected area 3) are the equipotential line (at least 4 mm ² copper)
is connected to the appropriate agencies. Schematic is attached.

4.

Appointments clauses:

The warranty is required by law during the period from the date of purchase. This must be the basis of a cash card or a payment 
document - the name of the dealer and the date of sale aufscheinen -. 
Customer Services for Sales Territory Austria: It will only be reported in writing customer service jobs, as performed, for example, 
guaranteed rates, or accepted if this is proven by a written message with proof of purchase (cash receipt) ... the service there.  
The warranty covers repairs and replacement of components of the device, which must be recognized by the company 
SANOTECHNIK. The intervention fee is payable by the customer, which is payable directly to the customer service. But not on 
installation and removal, and all other costs, these are excluded. Operational noises do not justify a complaint. 
Excluded from the warranty, defective parts, whose failure to negligence, improper use, use-wear, improper installation, 
maintenance by unlicensed personnel, are due damage in transit, such as backups, for example, decorative elements, etc. 
By poor compliance with the instructions of the manufacturers of any direct or indirect liability declines to persons or property.  
Indirect damage, w. for example, consequential damages due to lack of use or removal of any manufacturer is not liable. 
For repairs after the warranty period, the parts replaced, in work and travel expenses - according to the applicable rates set - into 
account. The current rates of fees, you can ask your customer service. 

Summary of Contents for TR20

Page 1: ...nloads Montaggio in Tempi Record Guarda il video dimostrativo www sanotechnik it SANOTECHNIK IT ViaPistelli19 92024 Canicatt AG Italia P IVA 02649080849 Tel 09221807908 Email sanotechnikitalia gmail c...

Page 2: ...posteriore Back wall H tfal zadn st na Partea din spate hrbtni panel zadnja panel Zadn stena Arka Panel 8 22 Vite M4 25 Screw M4 25 Csavarok M4 25 rouby M4 25 uruburi M4 25 Vijaki M4x25 Vijci M4x25 Sk...

Page 3: ...rofili Profil Profil spojovacia li ta pre pevn as k ti Dikey Profil 23 2 Guarnizione T T gasket T t m t s T t sn n Cheder T T tesnilo T brtvilo T tesnenie T conta 24 2 Ante fisse Fix doors Fix vegfal...

Page 4: ...sizioni di legge in vigore ATTENZIONE Non consentito l uso di tubazioni rigide tra la doccia e la fornitura di acqua Il collegamento deve essere flessibile in modo da essere possibile in qualsiasi mom...

Page 5: ...tit Perdite d acqua al di fuori box doccia pu verificarsi anche quando le articolazioni docce vengono direttamente spruzzate con acqua Eventuali piccole macchie punti o graffi sui pannelli posteriori...

Page 6: ...3 4 22 21 4 22 21...

Page 7: ...4 9 17 19 11 8 12 14 4 24 4 22 4 31 30...

Page 8: ...5 28 25 26 26 29...

Page 9: ...6 12 12 22...

Page 10: ...7 Silikon...

Page 11: ...8 Connessioni Idrauliche TR250 Doccetta Soffione Acqua fredda r Acqua calda Massaggio piedi Getti...

Page 12: ...9 Connessioni Idrauliche TR25 Doccetta Soffione Acqua fredda r Acqua calda Massaggio piedi Ingresso acqua Getti...

Page 13: ...Connessioni Elettriche 10...

Page 14: ...pannello del computer deve essere installato da persona qualificata La tensione di alimentazione AC 230 10 Si prega di spegnere il controllo dopo ogni utilizzo Scollegarlo quando non viene utilizzato...

Page 15: ...nel 13 14 IMPORTANT IMPORTANT IMPORTANT IMPORTANT The client have to guarantee that the complete shower cabin is mount in such way that every time it is free amenably to make overhauls or repair work...

Page 16: ...le extensible intermediate 50 cm between the siphon and sewer connection be installed so that a push back for maintenance or service is possible 3 Electrical installation On site The electronic connec...

Page 17: ...eared up the shower tray 14 Install the drain pipe 2 Connect the middle panel 7 with the side panel 12 and 16 with the screws M4 25 and put the parts on the shower tray 3 Screw the bend rails 4 on bou...

Page 18: ...ENGLISH ENGLISH ENGLISH ENGLISH ENGLISH ENGLISH 3 4 22 21 4 22 21...

Page 19: ...ENGLISH ENGLISH ENGLISH ENGLISH ENGLISH ENGLISH 4 9 17 19 11 8 12 14 4 24 4 22 4 31 30...

Page 20: ...ENGLISH ENGLISH ENGLISH ENGLISH ENGLISH ENGLISH 5 28 25 26 26 29...

Page 21: ...ENGLISH ENGLISH ENGLISH ENGLISH ENGLISH ENGLISH 6 12 12 22...

Page 22: ...ENGLISH ENGLISH ENGLISH ENGLISH ENGLISH ENGLISH 7 Silikon...

Page 23: ...ENGLISH ENGLISH ENGLISH ENGLISH ENGLISH ENGLISH 8 Water connections TR20 D sen Topshower Handshower Cold water Hot water Footmassage Jets...

Page 24: ...ENGLISH ENGLISH ENGLISH ENGLISH ENGLISH ENGLISH 9 Water connections TR25 Jets Cold water Footmassage Hot water Topshower Handshower Water inlet...

Page 25: ...ENGLISH ENGLISH ENGLISH ENGLISH ENGLISH ENGLISH Electrical connections 10...

Page 26: ...the low end 88MHz Then press the tune key the radio will begin to make automatic tuning from the low end to the high end again repress the radio key to turn off the radio 7 Press the Volume up or down...

Reviews: