18
ENGLISH
MILANO S
FOREWORD
This manual will teach you all you need to know to use and store your coffee
machine.
Please read all instructions very carefully before you actually use your machine
to make sure the machine works properly and to ensure a long working life.
Instructions are part of the product.
Please keep this document. This booklet refers to the following models:
Model – MILANO S SED
Electronic model controlled by microprocessor with dispensing programmable
through special pushbutton panel with indicator lights and switch for continual
manual dispensing. Available in 2 and 3 groups versions.
SPECIFICATIONS
GROUPS
2
3
Width
mm
705
935
Depth
mm
550
550
Height
mm
573
573
Capacity
l
12
19
Frequency
Hz
50-60
50-60
Supply voltage
V
220-240 1N~
380-415 3N~
220-240 1N~
380-415 3N~
Heating element input
kW
2,7/4,5
5,1
Cup heating element input
kW
0,2
0,25
Electric pump input
kW
0,15
0,165
External electric pump input
kW
0,15
0,187
Solenoid valve input
kW
0,0225
0,0315
Automatic level control input
kW
0,01
0,01
Boiler design pressure
(2 Bar) MPa
0,2
0,2
Boiler working pressure
(0,8-1 Bar) MPa
0,08:0,1
0,08:0,1
Safety valve calibration pressure
(1,8 Bar) MPa
0,18
0,18
Exchanger design pressure
(20 Bar) MPa
2
2
Exchanger safety valve calibration pressure
(12 Bar) MPa
1,2
1,2
Mains water pressure (max)
(6 Bar) MPa
0,6
0,6
Coffee dispensing pressure
(8-9 Bar) MPa
0,8/0,9
0,8/0,9
Summary of Contents for MILANO S
Page 2: ......
Page 4: ......
Page 6: ......
Page 20: ...20 ENGLISH MILANO S INSTALLING THE POWER SUPPLY CABLE ...
Page 29: ......
Page 44: ...44 FRANCAIS MILANO S SCHÉMA DE MONTAGE DU CÂBLE D ALIMENTATION ...
Page 53: ......
Page 56: ...56 ESPAGNOL MILANO S ESQUEMA DE INSTALACIÓN DEL CABLE DE ALIMENTACIÓN ...
Page 65: ......
Page 66: ......
Page 67: ...Cod 80011146 Agg 12 2017 ...