02-2014
VERONA RS
EN
Instructions for use and maintenance
13 / 29-EN
5
6
7
8
9
12
13
1
14
14
2
3
11
•
Position a jug of water and insert the tap (13) into
it.
Open the steam tap by turning tap (1) and try to
heat water up.
Repeat the same operation with the other dispenser
on the other side of the machine.
•
Assemble the filter holders (14) in the units, position
the cups under them and dispense by pressing one
of the buttons (5), (6), (7), (8) according to the filter
holder that was assembled (see the OPERATION
paragraph).
•
During dispensing, check that the pump pressure
shown by pressure gauge (11) is approx. 9 bar.
WARNING: during dispensing,
check that the pump pressure is
between 0.9 and 1 Bar (0.09 - 0.1
MPa).
If pressure is not within range "A", it
must be adjusted. Call the Technical
service for the adjustment.
•
Turn off the machine by bringing the main switch
(2) to “O”.
The LEDs (3) and displays turn off.
Close the water supply with the relevant tap.