41
Phase control
Intermittent cycle
control
Continuous cycle
control
Feedback
control
Available
Available
Not available
Responsiveness High speed
Middle speed
Low speed
Harmonics
May occur
Can be reduced
Flickering
None
May occur
May occur
(May be reduced with
the delay function)
Phase control Intermittent cycle control Continuous cycle control
F101: Temperature controller type
Select the temperature controller type.
Code
Function name
Setting range
Increment
Unit
Default
value
Changeable
during
operation
F2_P
Priority of the
temperature
controller signal
(P)
0: Control terminal
block input
0
✗
F2_H
Priority of the
upper limit signal
(H)
1: Panel
–
–
0
✗
F2_L
Priority of the
lower point
signal (L)
2: Communication
0
✗
F2_F
Priority of the
gradient signal
(F)
0
✗
Output voltage
Output cycles
(effective value)
Output cycles
(effective value)