44
In the panel operation example, this point is adjusted.
This function is used to set the optional conversion board.
Code
Function name
Setting range
Increment
Unit
Default
value
Changeable
during
operation
F400
Feedback
control method
0: No feedback
1: Constant current
control
2: Constant voltage
control
3: Constant power
control
–
–
0
✗
F401
Heater
disconnection
detection
function
0: Disable standard
version
1: Disable highly
functional version
2: Enable standard
version
3: Enable highly
functional version
–
–
0
✗
F402
Heater A count
1
to
5
1
–
2
✗
0.0%
10.0%
20.0%
30.0%
40.0%
50.0%
60.0%
70.0%
80.0%
90.0%
100.0%
0.0%
20.0%
40.0%
60.0%
80.0%
100.0%
Ou
tpu
t
v
olta
g
e
Setting
No.0(linearity)
No.1(1.6th root characteristic)
No.2(1.8th root characteristic)
No.3(2.0th root characteristic)
No.4(2.2th root characteristic)
No.5(2.5th root characteristic)
No.6(3.0th root characteristic)
No.7(average characteristic)