49
Code
Function name
Setting range
Increment
Unit
Default
value
Changeable
during
operation
F609
Er.09:
Emergency stop
–
–
0
✗
F610
Er.10: Power
supply voltage
drop
–
–
2
✗
F611
Er.11:
Instantaneous
voltage drop
–
–
2
✗
F612
Er.12: Frequency
error
–
–
2
✗
F613
Er.13: Heater
disconnection
–
–
2
✗
F614
Er.14: Self-
diagnosis
Load open error
–
–
2
✗
With this function, the output destination of the external warning relay signal, which is output
when an error occurs, can be selected for each error code. For details on the error codes, see
※
This function does not disable the error detection. It is used to simply switch the relay
contact output destination. The settings of this function do not change the output
stoppage, error code display, and other operations taken when an error occurs.
When [0: No output] is selected
The external warning relay signal is not output. This setting does not disable the error
detection.
When [1: Output to 1A-1C] is selected
The signal is output to 1A-1C (external warning relay [1]) on the control terminal block.
When [2: Output to HA-HC] is selected
The signal is output to HA-HC (external warning relay [2]) on the control terminal block.
When [3: Output to both] is selected
The signal is output to both 1A-1C (external warning relay [1]) and HA-HC (external
warning relay [2]) on the control terminal block.