87
15
OPTIONAL ITEM SPECIFICATIONS
Item
Specifications
Conversion
board
Constant current
control
characteristics
(when the built-in
CT is used)
Power supply
voltage fluctuation
Rated voltage ± 10%
±5% FS
Load
10 times the rated load
±5% FS
Ambient
temperature
–10°C to +50°C
±5% FS
Constant current
control
characteristics
(when the
external CT is
used)
Power supply
voltage fluctuation
Rated voltage ± 10%
±1% FS
Load
10 times the rated load
±2% FS
Ambient
temperature
–10°C to +50°C
±2% FS
Constant voltage
control
characteristics
Power supply
voltage fluctuation
Rated voltage ± 10%
±1% FS
Load
10 times the rated load
±1% FS
Ambient
temperature
–10°C to +50°C
±2% FS
Constant power
control
characteristics
(when the built-in
CT is used)
Power supply
voltage fluctuation
Rated voltage ± 10%
±5% FS
Load
10 times the rated load
±5% FS
Ambient
temperature
–10°C to +50°C
±5% FS
Constant power
control
characteristics
(when the
external CT is
used)
Power supply
voltage fluctuation
Rated voltage ± 10%
±1% FS
Load
4 times the rated load
±5% FS
Ambient
temperature
–10°C to +50°C
±3% FS
Constant power
control
characteristics
(built-to-order
board)
Power supply
voltage fluctuation
Rated voltage ± 10%
±1% FS
Load
10 times the rated load
±1% FS
Ambient
temperature
–10°C to +50°C
±1% FS