67
SECTION 9- ROUTINE MAINTENANCE
9.0
ROUTINE MAINTENANCE
Routine inspection and testing (power source)
An inspection of the power source, an insulation resistance test and an earth resistance test
should be carried out
a)
For transportable equipment, at least once every 3 months; and
b)
For fixed equipment, at least once every 12 months.
The owners of the equipment shall keep a suitable record of the periodic tests.
The only routine maintenance required for the power supply is a thorough cleaning and
inspection, with the frequency depending on the usage and the operating environment.
WARNING:
Disconnect Primary power at the source before opening the enclosure. Wait
at least two minutes before opening the enclosure to allow the primary
capacitors to discharge
To clean the unit, open the enclosure (see Section 9.1, Opening The Enclosure) and use a
vacuum cleaner to remove any accumulated dirt and dust. The unit should also be wiped clean, if
necessary; with solvents that are recommended for cleaning electrical apparatus.
Do not blow air into the power supply during cleaning. Blowing air into the unit
can cause metal particles to interfere with sensitive electrical components and
cause damage to the unit.
Summary of Contents for SANARG 200AP
Page 2: ......
Page 4: ......
Page 8: ......
Page 24: ...24 PAGE LEFT INTENTIONALLY BLANK ...
Page 35: ...35 Figure 3 2 Electrical Input Connections 200AP ...
Page 60: ...60 PAGE LEFT INTENTIONALLY BLANK ...
Page 66: ...66 PAGE LEFT INTENTIONALLY BLANK ...
Page 79: ...79 PAGE LEFT INTENTIONALLY BLANK ...
Page 80: ...80 10 1 INTERCONNECT DIAGRAM 200AP ...
Page 81: ...81 ...
Page 82: ...82 10 2 EXPLODED VIEW 200AP ...
Page 83: ...83 ...
Page 84: ...84 PAGE LEFT INTENTIONALLY BLANK ...
Page 89: ...PAGE LEFT INTENTIONALLY BLANK ...