44
enough adequate cooling for ROC and expander chip, user can remove the attaching fan on the
big passive heat sink.
The “Controller Fan Detection” function is available in the firmware for detecting the cooling fan
function on the ROC which uses the active cooling fan. When using the passive heatsink on the
controller, disable the “Controller Fan Detection” function through this McBIOS RAID manager
setting. The following screen shot shows how to change the McBIOS RAID manager setting to
disable the warning beeper function.
3.7.5.12.
Auto Activate Raid Set
When some of the disk drives are removed in power off state or boot up stage, the RAID set
state will change to “Incomplete State”. But if a user wants to automatically continue to work
while the SAS RAID controller is powered on, then user can set the “Auto Activate Raid Set”
option to “Enabled”. The RAID state will change to “Degraded Mode” while it powers on.
3.7.5.13.
Disk Write Cache Mode
User can set the “Disk Write Cache Mode” to Auto, Enabled, or Disabled. “Enabled” increases
speed, “Disabled” increases reliability.