Electrical Requirements
Wiring Schematic
The Santa Fe Rx plugs into a common grounded 115VAC outlet. The device draws 5.4 Amps at 80°F and 60% RH.
Locate the dehumidifier in an area where the cord’s length (10') easily reaches a 115 VAC electrical outlet with a minimum
of 15 Amp circuit capacity. If used in an area that may become wet, a GFCI protected circuit is recommended. The unit
should not be used in areas prone to flooding. Consult local electrical codes for any further information.
An optional remote dehumidistat is available for use with the Santa Fe Rx and is to be located remotely from the
dehumidifier.
CAUTION!
ELECTRICAL SHOCK HAZARD: Electrical power must be present to perform some tests. These tests should be
performed by a qualified service person.