background image

 

• 

sales@Santa-Fe-Products.com

 

TS-692 11/11

For small usage:

4201 Lien Rd., Madison, WI 53704 

 TOLL-FREE 1-800-533-7533 

 www.Santa-Fe-Products.com

Free-standing Moisture Control for Large Areas

n

  High capacity

n

  High efficiency

n

  Environmentally friendly

n

  Patent pending dual-air distribution

INSTALLER’S & OWNER’S MANUAL

P/N 4032230  •  Serial No.________________________ Install Date:___________ 
Sold by:

Patent Pending Dual-Air Distribution

PATENTS:  
D570,988 
8,069,681

Summary of Contents for IMPACT XT

Page 1: ...oducts com Free standing Moisture Control for Large Areas n High capacity n High efficiency n Environmentally friendly n Patent pending dual air distribution INSTALLER S OWNER S MANUAL P N 4032230 Ser...

Page 2: ...ile it is plugged in Do not sit or stand on the unit or use as a shelf or table Before leaving the unit unattended ensure children do not have access to the equipment Do not allow children to play wit...

Page 3: ...of a wall or obstruction Do not place the unit near open water 4 1A No Ducting fig 1 The simplest installation is to place the Santa Fe Impact with no ducting To ensure optimal performance the air inl...

Page 4: ...r proper drainage the unit must be mounted so the drain outlet is at least 4 above the floor drain and must be fully supported under the base 4 3 Condensate Water Removal Condensate drains by gravity...

Page 5: ...ta Fe Impact ships with a standard MERV 11 efficient pleated fabric filter This should be checked every six months The pleated fabric filter can generally be vacuumed clean several times before needin...

Page 6: ...ch AUTO but compressor cycles on off 1 Low ambient temperature and or humidity causing unit to cycle through defrost mode 2 Defrost thermostat defective 3 Defective compressor overload 4 Defective com...

Page 7: ...the factory mounted humidity control on the cabinet of the dehumidifier and allows you to accurately sense the humidity in an area other than the one where the dehumidifier is located Santa Fe Impact...

Page 8: ...s to a Product or Component that may be required by any codes laws or regulations that may become effective after initial purchase of the Product by Customer Customer Responsibilities As a further con...

Page 9: ...uced or transmitted in any form or by any means electronic or mechanical for any purpose without the express written permission of Therma Stor LLC 2008 Therma Stor LLC All rights reserved PO Box 8680...

Reviews: