background image

6

3. S

YSTEM

 D

ESCRIPTION

6K

Battery Pack for 1KS/2K(S)/3K(S)

Battery Pack for 6K

Intelligent

Output

Surge

Input

External

battery

Output

Communication port

Output

Input

2KS/3K(S)

Output

fuse

Output

socket

Input

breaker

Intelligent

slot

Input/

output

terminal

External battery

socket

Surge

protection

Communication

port

(RJ45)

breaker

breaker

fuse

Summary of Contents for C1KR(S)

Page 1: ...USER MANUAL RACK MOUNT 1 2 3 6kVA...

Page 2: ...ance 7 4 1 Operation Environment 7 4 2 Battery Application 7 4 3 Troubleshooting 7 5 Technical Data 9 5 1 Electrical Specification 9 5 2 Typical Stored Energy Time 9 5 3 Mechanical Data 9 5 4 Standard...

Page 3: ...y for fileservers minicomputers Internet hubs telecommunication systems and other mission critical applications It can auto restart while AC source restored after discharge shutdown and it also can su...

Page 4: ...es in such a way that no one can step on or trip over them Do not connect household appliances such as hair dryers to the UPS output sockets The UPS can be operated by any individuals with no previous...

Page 5: ...ries No other persons should handle the batteries Caution risk of electric shock The battery circuit is not isolated from the input voltage Hazardous voltages may occur between the battery terminals a...

Page 6: ...ity of the live conductor L and the neutral conductor N of site wiring reversed UPS ON LED Lights up when output power is supplied by the mains power via the inverter BATTERY LED Lights up when the ma...

Page 7: ...f the UPS and the battery packs are shown as below INDICATOR 1 5 Shows the load level in utility power mode Shows the battery level in battery mode 1K S Only available for 1KS Output socket Intelligen...

Page 8: ...k for 6K Intelligent Output Surge Input External battery Output Communicationport Output Input 2KS 3K S Output fuse Output socket Input breaker Intelligent slot Input output terminal External battery...

Page 9: ...together to achieve desired run time Notes It is suggested that one battery pack can be connected with one UPS main unit Only the identical battery packs can be connected in parallel to the models wi...

Page 10: ...the polarity of site wiring or building wiring AC INPUT LED blinks and BATTERY LED lights up Input power and or frequency are out of tolerance The UPS is now running in battery mode To save your data...

Page 11: ...MODE Notes Backup time of S models please consult the distributor Typical values at 25 C in minutes Model C1KR C1KRS C2KR C2KRS C3KR C3KRS C6KR INPUT Voltage 220VAC Frequency 46 Hz 54 Hz Adjustable Am...

Page 12: ...8 bits Ending Bit 1 bit Parity Bit none 1K S 2K S 3K S Conducted Emission EN50091 2 Class B Radiated Emission EN50091 2 Class B Harmonic Current EN61000 3 2 Voltage Fluctuations and Flicker EN61000 3...

Page 13: ...ion of DB 9 connector in AS400 card 5 TECHNICAL DATA 5 5 1 RS232 INTERFACE The following is the pin assignment and description of DB 9 connector Pin Description I O 2 RS232Tx Output 3 RS232 Rx Input 5...