Surge Protection(RJ45 Port):

  This is a transient voltage surge-suppressor for network

or fax/modem protection.

Communication Port:

  WinPower software can be used with the UPS for power

management. Standard serial interface cable is compatible with 1K(S)/2K(S)/3K(S)
UPS, however, only the special cable supplied with the UPS can be used on 6K UPS.

Input/Output:

  If socket is available, just insert compatible cable plug. If terminal is

available, qualified electrician should be required for wiring and installation.

Note

: Terminal cover should be put back for safety reason after wiring completed.

Input Breaker:

  If the breaker is tripped, reduce the load connected to the UPS and reset

the breaker.

External Battery Socket:  

Dedicated battery power cable is supplied with the battery

pack. Insert the cable into the external battery socket on the UPS and battery pack output
socket separately to connect battery pack to the UPS. The same battery packs can be
daisy chained together to achieve desired run time.

Notes

: It is suggested that one battery pack can be connected with one UPS main unit.

Only the identical battery packs can be connected in parallel to the models with suffix 

S

to extend the backup time .Please consult the distributor for further information.

3. S

YSTEM

 D

ESCRIPTION

4.1  O

PERATION

 

ENVIRONMENT

Ambient Temperature: 0

°

C to 40

°

C

Height of sea level < 1000m
Relative humidity: <95%

4.2  B

ATTERY

 

APPLICATION

Simply connect the UPS  to the mains to fully charge the  batteries  for 12 hours prior to
use  is recommended. It can also be used  immediately  without charging the batteries
first  but  the backup time will be less  than standard level.
Under normal conditions, the  battery  life lasts 3 to 5 years. In case if  the battery is found
not in good condition, earlier replacement should be made. The replacement of the
battery should be carried  out by qualified service personnel . Please contact  the
distributor .
The battery  should be charged once every three months for at least 12 hours. In areas
with higher temperatures, the battery should be charged once every two months and
each charging period shall be at least 12 hours.

Summary of Contents for C1KR(S)

Page 1: ...USER MANUAL RACK MOUNT 1 2 3 6kVA...

Page 2: ...ance 7 4 1 Operation Environment 7 4 2 Battery Application 7 4 3 Troubleshooting 7 5 Technical Data 9 5 1 Electrical Specification 9 5 2 Typical Stored Energy Time 9 5 3 Mechanical Data 9 5 4 Standard...

Page 3: ...y for fileservers minicomputers Internet hubs telecommunication systems and other mission critical applications It can auto restart while AC source restored after discharge shutdown and it also can su...

Page 4: ...es in such a way that no one can step on or trip over them Do not connect household appliances such as hair dryers to the UPS output sockets The UPS can be operated by any individuals with no previous...

Page 5: ...ries No other persons should handle the batteries Caution risk of electric shock The battery circuit is not isolated from the input voltage Hazardous voltages may occur between the battery terminals a...

Page 6: ...ity of the live conductor L and the neutral conductor N of site wiring reversed UPS ON LED Lights up when output power is supplied by the mains power via the inverter BATTERY LED Lights up when the ma...

Page 7: ...f the UPS and the battery packs are shown as below INDICATOR 1 5 Shows the load level in utility power mode Shows the battery level in battery mode 1K S Only available for 1KS Output socket Intelligen...

Page 8: ...k for 6K Intelligent Output Surge Input External battery Output Communicationport Output Input 2KS 3K S Output fuse Output socket Input breaker Intelligent slot Input output terminal External battery...

Page 9: ...together to achieve desired run time Notes It is suggested that one battery pack can be connected with one UPS main unit Only the identical battery packs can be connected in parallel to the models wi...

Page 10: ...the polarity of site wiring or building wiring AC INPUT LED blinks and BATTERY LED lights up Input power and or frequency are out of tolerance The UPS is now running in battery mode To save your data...

Page 11: ...MODE Notes Backup time of S models please consult the distributor Typical values at 25 C in minutes Model C1KR C1KRS C2KR C2KRS C3KR C3KRS C6KR INPUT Voltage 220VAC Frequency 46 Hz 54 Hz Adjustable Am...

Page 12: ...8 bits Ending Bit 1 bit Parity Bit none 1K S 2K S 3K S Conducted Emission EN50091 2 Class B Radiated Emission EN50091 2 Class B Harmonic Current EN61000 3 2 Voltage Fluctuations and Flicker EN61000 3...

Page 13: ...ion of DB 9 connector in AS400 card 5 TECHNICAL DATA 5 5 1 RS232 INTERFACE The following is the pin assignment and description of DB 9 connector Pin Description I O 2 RS232Tx Output 3 RS232 Rx Input 5...

Reviews: