Instructions to User 

Dear Users, thank you very much for purchasing our product. 
The  Manual  is  written  for  the  current  Pulse  Oximeter.  In  case  of  modifications  and  software  upgrades,  the 
information contained in this document is subject to change without notice. 
The  Manual  describes,  in  accordance  with  the  Pulse  Oximeter's  features  and  requirements,  main  structure, 
functions,  specifications,  correct  methods  for  transportation,  installation,  usage,  operation,  repair,  maintenance 
and storage, etc. as well as the safety procedures to protect both the user and equipment. Refer to the respective 
chapters for details. 
Please  read  the  Manual  very  carefully  before  using  this  equipment.  These  instructions  describe  the  operating 
procedures  to  be  followed  strictly;  failure  to  follow  these  instructions  can  cause  measuring  abnormality, 
equipment  damage  and  personal  injury.  The  manufacturer  is  NOT  responsible  for  the  safety,  reliability  and 
performance  issues  and  any  monitoring  abnormality,  personal  injury  and  equipment  damage  due  to  user's 
negligence of the operating instructions. The manufacturer's warranty service does not cover such faults.   
Owing to    forthcoming renovation(s), the specific products you received may not be totally in accordance with 
the description of this User Manual. We would sincerely regret for that.   
This product is a pulse oximeter and can be used repeatedly. Its’ useful life is 3 years.   

WARNING: 

 

An uncomfortable or painful feeling may appear if using the device ceaselessly, especially for 
microcirculation barrier users. It is recommended that the sensor should not be applied to the same 
finger for over 2 hours. 

 

For individual users, there should be a more prudent inspecting in the placing process. The device can 
not be clipped on the edema and tender tissue. 

 

The light (the infrared is invisible) emitted from the device is harmful to the eyes, so the user and/or 
the maintenance persons, can not stare at the light. 

 

Testee can not use enamel or other makeup. 

 

Testee’s fingernail cannot be too long. 

 

This device is not intended to diagnose or treat any medical condition or disease. It is intended for 
non-medical use in healthy people to monitor their pulse and blood oxygen levels during sports and/or 
aviation only.   

The User Manual is published by our company. All rights reserved. 

1 Safety 

1.1 Instructions for Safe Operations 

 

Check the main unit and all accessories periodically to make sure that there is no visible damage that may 
affect the user’s safety and monitoring performance about cables and transducers. It is recommended that 
the device should be inspected once a week at least. When there is obvious damage, stop using the monitor. 

 

Necessary maintenance must be performed by qualified service engineers ONLY. Users are not permitted to 
maintain it by themselves. 

 

The oximeter cannot be used together with devices not specified in the User's Manual. Only accessories that 
are provided or recommended by the manufacture can be used with this device. 

 

This product is calibrated before leaving the factory. 

1.2 Warnings 

 

Explosive hazard—DO NOT use the oximeter in an environment with flammable gas such as some ignitable 
anesthetic agents. 

 

DO NOT use the oximeter while the testee is being measured by MRI and/or CT. 

 

A person who is allergic to rubber cannot use this device. 

 

The disposal of scrap instruments and their accessories and packings (including batteries, plastic bags, foam 
and paper boxes) should follow local laws and regulations. 

 

Please check the packing before use to make sure the device and accessories are totally in accordance with 
the packing list, or else the device may have the possibility of working abnormally.   

 

Please don't measure this device with function test paper for the device's related information. 

1.3 Attentions 

 

Keep the oximeter away from dust, vibration, corrosive substances, explosive materials, high temperature 
and moisture. 

 

If the oximeter gets wet, please stop operating it. 

 

When  it  is  carried  from  a  cold  environment  to  a  warm  or  humid  environment,  please  do  not  use  it 
immediately.   

 

DO NOT operate buttons on front panel with sharp materials. 

 

High temperature or high pressure steam disinfection of the oximeter is not permitted. Refer to User Manual 
in the relative chapter for instructions of cleaning and disinfection. 

 

Do not have the oximeter submerged in liquid. When it needs cleaning, please wipe its surface with medical 
alcohol by soft material. Do not spray any liquid on the device directly. 

 

When cleaning the device with water, the temperature should be lower than 60°C/140°F. 

 

As to the fingers which are too thin or too cold, it would probably affect the normal measure of the users' 
SpO

2

 and pulse rate; please clip the thick finger such as thumb and middle finger deeply enough into the 

probe. 

 

Do not use the device on infant or neonatal users. 

 

The product is suitable for children above four years old and adults (Weight should be between 15kg/33lb to 
110kg/242lb).   

 

The device may not work for all users. If you are unable to achieve stable readings, discontinue use. 

 

The update period of data is less than 5 seconds, which will vary according to different individual pulse rate. 

 

The waveform is normalized. Please read the measured value when the waveform on screen is equably and 
steady-going, Here this measured value is optimal value. And the waveform at the moment is the standard 
one. 

 

If some abnormal conditions appear on the screen during the test process, pull out the finger and reinsert to 
restore normal use. 

 

The device has normal useful life of three years since the first electrified use.   

 

The  hanging  rope  attached  to  the  product  is  made  from  Non-allergenic  material;  if  particular  group  are 
sensitive to the hanging rope, stop using it. In addition, pay attention to the use of the hanging rope; do not 
wear it around the neck to avoid harm to the user. 

 

The instrument does not have a low-voltage alarm function, it only shows the low-voltage; please change 
the battery when the battery energy is used up. 

 

The  instrument  does  not  have  an  alarm  function.  Do  not  use  the  device  in  situations  where  alarms  are 

required.   

 

Batteries must be removed if the device is going to be stored for more than one month, or else batteries may 
leak. 

 

A flexible circuit connects the two parts of the device. Do not twist or pull on the connection. 

2 Overview 

The  pulse  oxygen  saturation  is  the  percentage  of  HbO

2

  out  of  the  total  Hb  in  the  blood,  so-called  the  O

concentration in the blood. It is an important bio-parameter for respiration. For the purpose of measuring the SpO

2

 

more easily and accurately, our company developed the Pulse Oximeter. At the same time, the device can measure 
the pulse rate 

2.1 Classification:   

Class II b, (MDD93/42/EEC    IX    Rule 10)

 

2.2 Features 

 

Operation of the product is simple and convenient. 

 

The  product  is  small  in  volume,  light  in  weight  (total  weight  is  about  50g  including  batteries)  and 
convenient in carrying. 

 

Power consumption of the product is low, and the two originally equipped AAA batteries can be operated 
continuously for 20 hours. 

 

The product will automatically be powered off when no signal is in the product within 5 seconds. 

2.3 Major Applications and Scope of Application 

This device is intended for non-medical use in healthy people to monitor their pulse and blood oxygen levels for 
sports  and/or  aviation  only.  Finger  should  not  be  moving,  it  should  be  stationary  while  using  the  oximeter, 
otherwise  it  will  give  inaccurate  results.  It  is  suitable  for  users  between  15  to  60  years  old.  Do  not  use  it  for 
continuous monitoring. 

 

2.4 Environment Requirements 

Storage Environment 
    a) Temperature :-40°C~+60°C 
    b) Relative humidity :≤95% 
    c) Atmospheric pressure :500hPa~1060hPa 
Operating Environment 
    a) Temperature :10°C ~40°C   
    b) Relative Humidity :≤75% 
    c) Atmospheric pressure :700hPa~1060hPa   

3 Principle and Caution 

3.1 Principle of Measurement 

Principle  of  the  Oximeter  is  as  follows:  An  experience  formula  of  data  process  is  established  taking  use  of 

Lambert  Beer  Law  according  to  Spectrum  Absorption  Characteristics  of  Reductive  Hemoglobin  (Hb)  and 

Oxyhemoglobin  (HbO

2

)  in  glow  &  near-infrared  zones.  Operation  principle  of  the  instrument  is:  Photoelectric 

Oxyhemoglobin  Inspection  Technology  is  adopted  in  accordance  with  Capacity  Pulse  Scanning  &  Recording 

Technology, so that two beams of different wavelength of lights can be focused onto a human nail tip through 

perspective  clamp  finger-type  sensor.  A  measured  signal  can  then  be  obtained  by  a  photosensitive  element, 

information  acquired  through  which  will  be  shown  on  screen  through  treatment  in  electronic  circuits  and 

microprocessor. 

 

Figure 1 Operating principle 

3.2 Caution 

1.

 

The finger should be placed properly (see the attached illustration of this manual ,Figure 5), or else it may 

cause inaccurate measurement. 

2.

 

The SpO

2

 sensor and photoelectric receiving tube should be arranged in a way with the subject’s arteriole in a 

position there between

 

3.

 

Make sure the optical path is free from any optical obstacles like rubberized fabric. 

4.

 

Excessive ambient light may affect the measuring result. It includes fluorescent lamp, dual ruby light, infrared 

heater, direct sunlight, etc. 

5.

 

Strenuous action of the subject or extreme electrosurgical interference may also affect the accuracy. 

6.

 

Testee cannot use enamel or other makeup.

 

 

7.

 

Due to the sensitivity of the pulse oximeter, you should keep your finger stationary during measurement. It is 

recommended that you use this instrument for measurement before or after sports. Do not use for continuous 

monitoring. 

4 Technical Specifications 

1)

 

Display Format:

 OLED Display; 

      SpO

2

 Measuring Range: 

0% - 100%; 

      Pulse Rate Measuring Range:

 30 bpm - 250 bpm; 

      Pulse Wave Display:

 columniation display and the waveform display. 

2)

 

Power  Requirements:

  2  ×1.5V  AAA  alkaline  battery  (or  using  rechargeable  battery  instead),  adaptable   

range: 2.6V~3.6V. 

3)

 

Power Consumption:

 Smaller than 30mA. 

4)

 

Resolution:

 1% for SpO

2

 and 1 bpm for Pulse Rate. 

5)

 

Measurement  Accuracy: 

±2%  in  stage  of  70%-100%  SpO

2

,  and  meaningless  when  stage  being  smaller         

than 70%. ±2 bpm or±2% (select larger) for Pulse Rate.   

6)

 

Measurement Performance in Weak Filling Condition:

 SpO

2

 and pulse rate can be shown correctly when 

pulse-filling ratio is 0.4%. SpO

2

 error is ±4%, pulse rate error is ±2 bpm or ±2% (select larger). 

7)

 

Resistance to surrounding light:

 The deviation between the value measured in the condition of man-made 

light or indoor natural light and that of darkroom is less than ±1%. 

8)

 

It is equipped with a function switch. The Oximeter can be powered off in case no finger is in the Oximeter 
within 5 seconds. 

9)

 

Optical Sensor

 

      Red light (wavelength is 660nm, 6.65mW)   
      Infrared (wavelength is 880nm, 6.75mW) 

5 Accessories 

 

One hanging rope and carrying case 

 

Two batteries (optional); 