One User Manual. 

6 Installation 

6.1 View of the Front Panel 

 

Figure 2 Front view 

6.2 Battery 

Step 1. Refer to Figure 3. and insert the two AAA size batteries properly in the right direction. 

Step 2. 

PLEASE LOOK AT + / - SIGN BEFORE INSTALLING THE BATTERY 

Step 3. Replace cover by sliding battery cover back on in line with inside tab. 

Please take care when you insert the batteries as the improper insertion may damage the device. 

 

 

 

Figure 3 Batteries installation 

(since we have used a new battery placement design, we will use the new placement instruction replace this 

paragraph) 

6.3 Mounting the Hanging Rope   

Step 1. Put the end of the rope through the hole. 

Step 2. Put another end of the rope through the first one and then tighten it. 

 

Figure 4 Mounting the hanging rope 

7 Operating Guide 

1)

 

Insert the two batteries properly to the direction, and then replace the cover. 

2)

 

Open the clip as shown in Figure 5.   

 

Figure 5 Put finger in position 

3)

 

Let the user’s finger go into the rubber cushions of the clip (make sure the finger is in the right position), and 

then clip the finger. 

4)

 

Press the switch button once on front panel. 

5)

 

Do  not  shake  the  finger  and  keep  the  user  at  ease  during  the  process.  Meanwhile,  human  body  is  not 

recommended to be in movement status. 

6)

 

Get the information directly from screen display. 

7)

 

The button 

  has three functions. When the device is powered off, pressing the button will turn it on; 

when  the  device  is  powered  on,  pressing  the  button  shortly  can  change  direction  of  the  screen;  when  the 

device is powered on, pressing the button long can change brightness of the screen. 

  Fingernails and the luminescent tube should be on the same side.

 

8 Repairing and Maintenance 

 

Please change the batteries when the low-voltage is displayed on the screen. 

 

Please clean the surface of the device before using. Wipe the device with medical alcohol first, and then let 

it dry in air or clean it by dry clean fabric.   

 

Please take out the batteries if the oximeter is not in use for a long time. 

 

The best storage environment of the device is - 40ºC to 60ºC ambient temperature and not higher than 95% 

relative humidity.   

 

Users  are  advised  to  calibrate  the  device  intermittently  .  It  also  can  be  performed  at  the  state-appointed 

agent or just contact us for calibration. 

  High-pressure sterilization cannot be used on the device.   

  Do not immerse the device in liquid. 

 

It  is  recommended  that  the  device  should  be  kept  in  a  dry  environment.  Humidity  may  reduce  the 

useful life of the device, or even damage it. 

9 Troubleshooting 

 

Trouble 

Possible Reason 

Solution 

The SpO

2

 

and Pulse 

Rate can not be 
displayed normally

 

1. The finger is not properly positioned. 
2. The user’s SpO

2

 is too low to be detected.   

1. Place the finger properly and try 
again.   
 

The SpO

2

 

and Pulse 

Rate are not 
displayed stably

 

1.

 

The  finger  is  not  placed  inside  deep 

enough. 
2.

 

The  finger  is  shaking  or  the  user  is 

moving. 

1. Place the finger properly and try 
again.   
2. Let the user keep calm   

The device can not 
be turned on

 

1. The batteries are drained or almost 
drained.   
2. The batteries are not inserted properly.   
3. The malfunction of the device. 

1. Change batteries. 
2. Reinstall batteries. 
3. Please contact the local service 
center. 

The display is off 
suddenly

 

1. The device will power off automatically 
when it gets no signal within 5 seconds. 
2. The batteries are almost drained. 

1. Normal. 
2. Change batteries. 

 

10 Key of Symbols 

 

Symbol 

Description 

 

Type BF 

 

Warning – See User Manual 

 

The pulse oxygen saturation (%) 

PRbpm

 

Pulse rate (bpm)

 

 

The battery voltage indication is deficient (change the battery in time avoiding 

the inexact measure) 

 

1. No finger inserted    2. An indicator of signal inadequacy 

 

Battery positive electrode 

 

Battery cathode 

 

1.Power switch    2. Change direction of the screen 3.Change brightness of the 

screen 

SN 

Serial number         

 

Alarm inhibit 

 

WEEE (2002/96/EC) 

IP22 

International Protection 

 

11 Function Specification 

 

Display Information 

Display Mode 

The Pulse Oxygen Saturation(SpO

2

OLED 

Pulse Rate(PR) 

OLED 

Pulse Intensity (bar-graph) 

OLED bar-graph display 

Pulse wave   

OLED 

SpO

2

 Parameter Specification 

Measuring range 

0%~100%, (the resolution is 1%). 

Accuracy 

70%~100%:±2%, Below 70% unspecified. 

Optical Sensor 

Red light (wavelength is 660nm) 

Infrared (wavelength is 880nm)   

Pulse Parameter Specification 

Measuring range 

30bpm~250bpm (the resolution is 1 bpm) 

Accuracy 

±2bpm or±2% select larger 

Pulse Intensity 

Range 

Continuous  bar-graph  display;  a  higher  display  indicates  a  stronger 

pulse. 

Battery Requirement 

1.5V (AAA size) alkaline batteries × 2 or rechargeable battery                                                                                                                             

Battery Useful Life 

Two batteries can work continually for 20 hours 

Dimensions and Weight 

Dimensions 

57(L) × 31(W) × 32(H) mm 

Weight 

About 50g (with the batteries) 

 