3.2.

 

List of the BASIC Measures and Parameters 

 

Menu 

Parameter 

FUNCTION 

MODBUS 

Address 

Default 

4 DATA LOGGER MENU 

P298 

Access Level 

298 BASIC 

 I012 

EEPROM Command 

2003 No 

Command 

 M475 

Software Version 

475 - 

 M5000 

Alarm Condition 

5000 - 

 M5003 

Active Access Level  

5003 - 

 M5004 

Flash Card Error 

5004 - 

 M5006 

MAC Address  

5006, 5007, 

5008 

 M5199 

Latest EEPROM command not 

executed 

5199 - 

 

 

 

 

 

8 LOG 1 MONITOR MENU 

M5050 

Log 1 Length 

5050 - 

 M5057 

Log 1 Status  

5057 - 

 M5070a-b 

Year and Month of Activation of Log 1 

5070 - 

 M5071a-b 

Day and Time of Activation of Log 1 

5071 - 

 M5072a-b 

Minutes and Seconds of Activation of 

Log 1 

5072 - 

 

 

 

 

 

8LOG 2 MONITOR MENU 

M5051 

Log 2 Length 

5051 - 

 M5058 

Log 2 Status  

5058 - 

 M5073a-b 

Year and Month of Activation of Log 2 

5073 - 

 M5074a-b 

Day and Time of Activation of Log 2 

5074 - 

 M5075a-b 

Minutes and Seconds of Activation of 

Log 2 

5075 - 

 

 

 

 

 

8 LOG 3 MONITOR MENU 

M5052 

Log 3 Length 

5052 - 

 M5059 

Log 3 Status  

5059 - 

 M5076a-b 

Year and Month of Activation of Log 3 

5076 - 

 M5077a-b 

Day and Time of Activation of Log 3 

5077 - 

 M5078a-b 

Minutes and Seconds of Activation of 

Log 3 

5078 - 

 

 

 

 

 

8 LOG 4 MONITOR MENU 

M5053 

Log 4 Length 

5053 - 

 M5060 

Log 4 Status  

5060 - 

 M5079a-b 

Year and Month of Activation of Log 4 

5079 - 

 M5080a-b 

Day and Time of Activation of Log 4 

5080 - 

 M5081a-b 

Minutes and Seconds of Activation of 

Log 4 

5081 - 

 

 

 

 

 

8 LOG 5 MONITOR MENU 

M5054 

Log 5 Length 

5054 - 

 M5061 

Log 5 Status  

5061 - 

 M5082a-b 

Year and Month of Activation of Log 5 

5082 - 

 M5083a-b 

Day and Time of Activation of Log 5 

5083 - 

 M5084a-b 

Minutes and Seconds of Activation of 

Log 5 

5084 - 

 

 

Summary of Contents for ES851

Page 1: ...tronica Santerno is responsible for the device in its original setting Any changes to the structure or operating cycle of the device must be performed or authorized by the Engineering Department of El...

Page 2: ...ers 12 3 3 List of the ADVANCED Measures and Parameters 14 4 DATA LOGGER MENU 16 5 DATA LOGGING CONSOLE MENU 20 6 SCAN DEVICE 11 40 MENU 29 7 UPLOAD CONSOLE MENU 33 8 LOG MONITOR MENU 34 9 EVENT MONIT...

Page 3: ...nized devices 31 Table 14 Bit map of the type of logging 31 Table 15 Bit map of Event 0 fired for the connected devices 32 Table 16 List of the measures in the Log Monitor menu 34 Table 17 Bit map of...

Page 4: ...al covers functionality and first startup of ES851 Data Logger board The RemoteDrive Sunway software provided by Elettronica Santerno allows full exploitation of ES851 Data Logger functionality The Re...

Page 5: ...e of the following modes Local mode through COM1 and COM2 ports RS232 RS485 or Ethernet port for a direct LAN Remote mode through the Ethernet port or a GPRS modem both connected via the Internet or t...

Page 6: ...ort RS232 Modbus RTU Set parameter R450 as 2 PROXY GPRS modem see the CONNECTION CONFIGURATION MENU In the parameters relating to the APN P3110 P3139 enter the APN of the provider such as ibox tim it...

Page 7: ...f their identifiers have been previously set to values higher than or equal to 3 Unique identifiers are to be assigned to avoid conflicts According to factory settings COM2 port is already set as Mast...

Page 8: ...for any boxed device To sum up do the following to activate the LOGGING function in the DATA LOGGING CONSOLE MENU Select the type of LOGGING from parameter C161 Press the SCAN button Activate LOGGING...

Page 9: ...og 3 Monitor Log 3 status Log 4 Monitor Log 4 status Log 5 Monitor Log 5 status Log 6 Monitor Log 6 status Event Monitor Event status Modbus Configuration Serial port configuration parameters TCP IP P...

Page 10: ...xxx Range Device representation integer Display on the display keypad and the RemoteDrive Sunway software may be a decimal figure plus unit of measure Level Access Level BASIC ADVANCED Address Modbus...

Page 11: ...OGGING function activated R W with LOGGING function deactivated Rxxx Parameters Always R W but they activate only when the device is next powered on Ixxx Inputs These are not parameters but inputs the...

Page 12: ...Log 2 Length 5051 M5058 Log 2 Status 5058 M5073a b Year and Month of Activation of Log 2 5073 M5074a b Day and Time of Activation of Log 2 5074 M5075a b Minutes and Seconds of Activation of Log 2 5075...

Page 13: ...f Log 6 5087 9 EVENT MONITOR MENU M5056 Evt Log Length 5056 M5063 Evt Log Status 5063 M5088a b Year and Month of Activation of Evt Log 5088 M5089a b Day and Time of Activation of Evt Log 5089 M5090a b...

Page 14: ...vices Detected when SCANNING 5016 M5017 Modbus ID of the Device being SCANNED 5017 C165 a C174 a ID of the Connected Device 165 174 0 C165 b C174 b Type of Connected Device 165 174 No device detected...

Page 15: ...P3150 P3177 Message Header 3150 3177 P580 SMS Mode 580 Proxy P294 SMS Sent After Event Disappeared 294 Yes 16 CLOCK CALENDAR MENU P2010a Year To Be Changed 2010 2000 P2010b Month To Be Changed 2010 Ja...

Page 16: ...log operation e g Erase Log affects ES851 Flash Card M5199 indicates the latest EEPROM command that has not been executed as well as the alarm tripped and its fault code Parameter FUNCTION Access Leve...

Page 17: ...hat can be accessed by the user 5 Save All The current value of the RAM parameters is stored to non volatile memory DATA FLASH All parameters are saved at a time 11 Restore Default Factory set values...

Page 18: ...alarm tripped for ES851 Please contact Elettronica Santerno and state the alarm number and name 0 No Alarm 1 Parameter Save Error 2 Log Write Error 3 FBS Configuration Error 4 Modbus RS232 Configurat...

Page 19: ...ss 5006 5007 5008 MAC Address Function The MAC Address is the physical address for ES851 network interface A unique MAC Address is assigned to each ES851 board M5199 Latest EEPROM Command Not Executed...

Page 20: ...nique to each device and which is stored to ES851 when factory setting is performed see APPENDIX Two log groups are available Fast Log C162 C163 C245 and Slow Log C242 C243 C244 which are characterize...

Reviews: