BASIC - ADVANCED
DATA LOGGER
PROGRAMMING INSTRUCTIONS
ES851
8/
66
NOTE
LOGGING is to be activated as the last installation step. Any procedure for the
connection configuration (see sections below) must be performed before LOGGING is
activated.
NOTE
The type of LOGGING (extended or standard logging) can be changed for any boxed
device.
To sum up, do the following to activate the LOGGING function in the “DATA LOGGING CONSOLE MENU”:
•
Select the type of LOGGING from parameter C161;
•
Press the SCAN button;
•
Activate LOGGING , I160 “ENABLE All Logs”.
2.5.
Parameter Save
After entering the new settings, execute the Eeprom command “5: Save All” (see the “DATA LOGGER MENU”) to keep
them stored even after ES851 is reset. If you are using the RemoteDrive/Sunway software, just press the S key after
changing a parameter, or send the Save All Command.