14
Warning: disconnect from all electrical supplies before beginning any work on the
unit. Water contained in the heater may be very hot.
To ensure the continued safe and efficient operation of the unit, it should be
regularly maintained.
Maintenance should be carried out by a competent person and any replacement
parts used should be authorised Santon spare parts.
Little maintenance is required, however in hard water areas the unit will require
periodic descaling to ensure efficient operation. To descale the unit:
6.1 Switch off and disconnect the electrical supply. Turn off the water supply to
the unit.
6.2 Open a hot tap to relieve any system pressure. Empty unit by opening the
drain cock in the inlet pipework.
6.3 Remove the terminal cover by using a large flat bladed screwdriver to
depress the 4 snap lugs located in the 4 rectangular depressions on the
bottom cover.
6.4 Disconnect the electrical terminations to the element. Disconnect earth links
to the earthing stud. Withdraw the thermostat and thermal cut-out capillary
tubes from the pocket on the element plate.
6.5 Remove the element plate assembly by unscrewing the five securing screws,
tapped jacking holes are provided (NOTE: a quantity of water may still be
present in the container, it is recommended that a container be placed under
the unit to collect any spillage). Remove any loose scale from the container.
Carefully clean off any scale from the element and thermostat pocket. DO
NOT clean scale from interior container walls.
6.6 Re-assemble the element plate assembly fitting a new sealing gasket. Rewire
the unit with reference to the Wiring Diagrams.
6.7 Re-commission the unit following the INSTALLATION and
COMMISSIONING instructions.
6.0 MAINTENANCE
Summary of Contents for Aquaheat AH30V