FAULT FINDING
Identify the exact cause of the appliance stoppage
The paddles do not turn:
x
Make sure that you have indeed actuated (position
1
) the respective switches (
8
)
x
Check the mains power supply and the condition of the power supply lead.
Liquid drips from the distribution nozzle:
x
Clean the flexible distribution spout (
5
) (a solid body is probable stuck inside).
x
The flexible spout (
5
) is a consumable. For hygiene reasons, do not hesitate to
replace it regularly
The appliance overheats:
x
Ventilation is required to ensure the proper performance of the appliance
x
Make sure that the front and back ventilation vents (
10
) are not obstructed (leave a
gap of at least 15cm).
x
Check that there is no dust on the condenser grid (clean using a soft brush)
o
Access to the grid: remove the appliance side panels (
9
)
The temperature of the juice is too high:
x
See previous section "
the appliance overheats
"
x
Depending on the volume of product and the ambient temperature, it is sometimes
necessary to wait several hours before reaching the desired temperature.
x
If after stabilisation the temperature is inadequate, then adjust the thermostats (
12
)
(one per juice container; it is recommended that the same setting is used on all the
thermostats)
o
Access to the thermostats: remove the appliance side panels (
9
)
x
For multi-container appliances (2 or 3 containers),
leaving at least one container
with no liquid is not recommended
.
o
Frost quickly forms on the evaporation cup (
4
) and the thermostat is quickly
triggered, thus stopping the compressor. The other containers are no longer
cooled.
o
Always fill the containers with a minimum of 5 cm of liquid
The appliance runs continually without cooling the juice:
x
Have the system checked by a refrigeration engineer
x
The refrigerant charge is stated on the appliance identification plate.
x
Draining and filling the condensing unit is absolutely prohibited in any place not
equipped to collect such gasses.
x
Do not use anything other than R134A