MAINTENANCE
Before carrying out any work on the cold press juicer, it must in all cases be unplugged
from the mains power supply and wait 20 seconds for the capacitor of the electronic
board to discharge:
Spare parts:
IMPORTANT
: The use of spare parts other than certified original SANTOS parts is
prohibited.
This machine requires no specific maintenance because the bearings are lubricated for
life.
If any intervention is necessary to replace parts subject to wear, such as the sieve
(
13/14
), the scrapers (
15
), the seals (
16
), (
18
), (
20
), (
21
), the electrical or other
components, please refer to the parts list (see the exploded view at the end of this
manual, or download from our website
www.santos.fr
).
For
all spare part orders
(see references in the exploded view at the end
of the manual), state the
type, the machine serial number and the
electrical specifications recorded under the machine.
SERVICING:
Neither a hose nor a pressure hose should be used for cleaning
After use, clean the plunger (
4
), the feed channel (
3
), the bowl (
1
), the top screw
(
11
), the bottom screw (
12
), the sieve (
13/14
), the scrapers (
15
), the discharge
cone (
17
), the seal (
18
), the ring (
19
) and the pulp container (
5
) in clean water or
with a dish washing detergent product designed for this purpose. Then rinse and
dry.
Do not use abrasive products or materials
to clean the basket assembly.
The base is to be cleaned with a soft damp sponge, then dried.
CAREFUL
:
For easier cleaning, do not leave food remains to dry on the parts in
contact with the food and clean all these parts of the machine
immediately after the work is finished.
FAULT FINDING
Identify exactly why the machine stopped
THE MACHINE WILL NOT START:
Check: the mains supply and the condition of the power supply cord.
!
!
408120 en ma 2017.09
10/18